Noob to the forum. Looking for CYA advice

Clean your test vial...rubbing alcohol and dry it. Try it again.
Also, what are the dimension of your pool? L/W shallow D and deep D?
Also, next time you add, wait 30 minutes and test FC, report that too.
Fc 12.5, CC 1.5
I think i should just continue testing it and see if the fc drops in a couple hours. What di you think?

Pool remodel... Add spa, plumbing, automation

Whirlwind of a few weeks... I did have time to go thru those pages.
What we want to do with automation. Turn on Spa mode, Pool mode, Bubbler, Spa Jets, Heater and lights.

We are going to simple it down.
So it would be a

Pool & Spillover Spa setup with a bubbler. Separate jet pump for Spa. Bubbler on pool mode.
2 pumps, Filter, Heater, SWG

So that puts me at 3 actuators.
Suction, Return and Bubbler (Pool mode)

On my HVRLs
1, Spa & Pool Lights. Ideally separate but have seen smart transformers.
2. Air Blower
3. Possibly (Whisperflo vst one speed jet pump)
4.
(2) expansion available

RS 485
1. Pump
2. Pump (if compatible)
3. Heater

Spa plumbing
Max 8 definitely jets. 6 on seating and 2 on lower. (Still debating if worth it for lower)
2 Drains to Filter, 2 drains to jet pump

What do you think Allen?


Suction
  • (2) Spa main drains (split by tee)
  • Pipe Size: 3" PVC dedicated suction line
  • Design Flow Rate: ~120 GPM total
  • Velocity in 3" Pipe @ 120 GPM: ~3.4 ft/sec (well within NSF-50 < 6 ft/sec limit)

Return

  • Jet Return Manifold: 2.5" PVC from pump
  • Branch to Jet Loop: Reduces to 1.5" for distribution
  • Jet Loop Configuration:
    • 8 jets, looped or manifolded evenly
    • Each jet delivers ~15 GPM
    • 8x15 120gpm
  • Velocity in 2.5" pipe @ 120 GPM: ~5 ft/sec
  • Velocity in 1.5" pipe sections (short runs): ~8.5 ft/sec (acceptable in spa jet loops)

Jandy Pro Series TruClear

That stinks, but is pretty typical for the TruClear.
Just FYI AquaPure and FusionSoft are also Jandy products. They have 3 SWG systems - you were sold the worst one. We tend to not recommend TruClear for these reasons...

Poolmath calculation of chemical cost per use

While I can think of a few issues in programing this, I'd like to learn more about your end goal. Can you explain to me in detail what you wish to do with this piece of information and how it would help you in maintaining your pool?
thank you. Let me update and attach the spreadsheet I use for maintenance cost to serve as guidance. Might take me to the weekend to send it.
Thank you for exploring it
  • Like
Reactions: Newdude

Sand filter making weird noise is this normal.

What sound are you talking about? I think I hear an air leak but can't be sure.
I have uploaded another video where you can hear a whining noise from the pump and a gurgling sound near the sand filter intake. Do you think I have an air leak? How can I confirm this, and what would be the fix?

Login to view embedded media

Attachments

  • IMG_7430.jpeg
    IMG_7430.jpeg
    351.6 KB · Views: 2

IMG_7430.jpeg

Let’s see your water after removing winter cover!! **RESURRECTED FOR 2025!**

Opened on May 10th this year. Looks like this every year after I pull the cover. Had to wait for some test chemicals before I could get the water chemistry where it's supposed to be. Another day or so and the water will be back to crystal clear. Fired up the heat pump but I don't think there is enough heat out there yet. Supposed to be in the 90s here mid week so that will help.

PXL_20250510_190415732.jpgPXL_20250510_190436280.jpg

PXL_20250510_190436280.jpg

PXL_20250510_190415732.jpg

Filter