Intro

Hello, new here, in central Illinois, been a pool owner for 5 years. Always went to the pool store, bought their products (bioguard) and had them test my water. i have had no issues till opening this year. cloudy water and no answers, so here I am, looking forward to taking control of my pool chemistry. i have a 13,500 galloon steel above ground with vinyl liner. sand filter and pump. also a heat pump heater.

iCHLOR 30

IMG_0755.jpeg
This picture shows a low salt error with the cell light off. The cell will not produce with a low salt condition, thus the cell light will be off.

IMG_0756.jpeg

This picture shows the cell at some production rate with the cell light on. Have you tested the actual salinity with a known good kit? If not you need to, it’s impossible to diagnose a cell without having a concrete baseline of what the salinity actually is. If you have please post the salinity numbers you have tested.

IMG_0756.jpeg

IMG_0755.jpeg

Cloudy Water

What type of cartridge filter do you have? Can you provide make and model? You mentioned that you put in new cartridges. Do you remember the pressure that was on the filter immediately after putting in the new cartridges? What is pressure now?

The concern is that you had an algae issue and not sure it has been completely removed. Or why the filter is not clearing it probably.
We have a Hayward XStream Full-Flo Element Filter System. The pressure putting the new cartridge in as about 15. As of tonight, 3 days later, it was probably 16.

mikeoliver.jpeg

iCHLOR 30

So new update kinda of. My salt LED light started working again for a few minutes then went off again and now I have this new like light next to the output amount all the way to the left
Please confirm you set production to 100% and the cell light stayed off……
Yes I set to 100% and salt cell light stayed off

Attachments

  • IMG_1124.jpeg
    IMG_1124.jpeg
    773.2 KB · Views: 10
  • IMG_1125.jpeg
    IMG_1125.jpeg
    500.3 KB · Views: 8

IMG_1125.jpeg

IMG_1124.jpeg

Circupool Core Control 55 Initial Thoughts

Interesting. I didn’t pay anywhere near that much.
Agreed I think I was under 2k when combining with a pump. Im looking forward to the automation that it'll include with the expanded platform..I don't have pool automation today. Im desperate for being able to monitor the pump if possible. What's happening now with the heater is if flow isn't high enough heater turns off. So for example I just took apart and cleaned my de filter. Added fresh de. Pool is spotless and solar cover is on it. Left the house for dinner with pump set to 1800 rpms...heater ran for an hour. At dinner I saw it stopped flowing.....so had to go home and now increase to 2000 rpms and heaters on again...

Wish I could control all of this remotely

Filter