Hayward variable speed pump question
- By Bill1974
- Pumps, Filters, and Plumbing
- 15 Replies
Get a meter out and check to see if the pump has power. As ajw22 stated the pumps display panel may be blank because it's disconnected. If the pump has no power, check the relay to see if there is power going in and out of it. If the pump has power than it is not getting a signal from the RS485 cable to run. Check to see if the controller is getting power. If you need to run the pump disconnect the controller and connect the panel on the pump and use that to manually run the pump. You may need do some wiring to get constant power to the pump.