pentair

  1. OmniPools

    Minimax Heater NT; NOT IGNITING

    Hey yall! So I've come across an issue with a clients minimax NT. This heater will not ignite for no one. Currently I'm receiving 120v in and out of the hot surface ignitor, I can see it turning RED. The gas valve is receiving 24v at the blue and white wires. Incoming Gas pressure is 8" wc...
  2. J

    Pentair Laminar Wiring

    Hello we are getting ready to install Pentair laminars that will be connected to intellicenter. Here is my layout.....1st laminar is about 60' from the intellicenter, 2nd is about 40' from 1st and 3rd is about 25' from the 2nd. (pic attached). So my question is, do i need to homerun a 1"...
  3. S

    Intellicenter - Freeze protection says it is on, but pump speed is 0

    Hello - I have a mystery. I have a intellicenter running two separate systems for pool and spa. When temp drops, both say that they are on freeze protection and the green light is on for both pumps on the app, but the spa pump flow is 0. I went and checked this morning, and the pump is not on...
  4. J

    Can Pentair EasyTouch handle more than four actuators?

    I am using the four ports already and I need one more for my last remodel. Is there a device I can use to add an extra port somehow? Thanks
  5. MaverickFL

    Review: New Pentair IntelliFlo3 VSF

    Finally an opportunity for a little bit of give back on this forum. With some support and encouragement from my friend @Jimrahbe I purchased this new Intelliflo3 VSF pump mostly because the previous model was infinitely backordered. I am so glad I did, so far I love this pump! Here is my...
  6. D

    Pentair Intelliflo 4 160 Alarm goes off and I cannot get it to work

    The pump had been leaking for a couple of years and I finally decided to replace it. I found the motor on amazon and so I ordered a new motor and seal plate. I kept the wet side and control panel from the original. After watching some videos I replaced the motor. Seemed like it went well...
  7. D

    Pentair Mastertemp 300 not working right after cleaning

    Hey everyone! New pool owner here. Bought a house with an existing 33k gallon in-ground pool with a Pentair Mastertemp 300 which has been working flawlessly for almost two seasons that I've owned it until I decided to clean it and I messed things up royally. First off, I was installing a wire...
  8. DavidArmenB

    Two terrible sounds from brand new Pentair VSF pump.

    First post! This forum has been a great resource ever since I became a first-time pool owner a few months ago! After replacing the old WhisperFlo pump with a brand new Intelliflo VSF, I have heard two different noises, which definitely don’t sound normal, coming from said pump. The first is...
  9. H

    New member from Pearland (Houston) Texas

    Hi there, I have experience with maintaining a simple chlorine pool with a single speed pump, single cartridge filter and cholorine tablet dispenser for a pool that's screened in. So low maintenance. Now we have a salt water pool, with pentair variable speed pump, pentair controler panel...
  10. Chgorob1

    Intellicenter Err message with Solar

    Has anyone familiar with Pentair IntelliCenter know what this err message means? See photo It also shows if I do solar preferred. Does not appear if I select Mastertemp400 heater, only solar
  11. J

    Talk me off the edge! (Automation, etc.)

    OK. I am pretty frustrated with my equipment (pump-swg), and I am considering starting over. I want my automation to work more smoothly, and I'd like to gain some reliability. What I have: Control: iAqualink 2.0 with the V2 board. Main Pump: A centry V-green pump. I have the V-Green...
  12. A

    iAquaLink 3.0 + Superflo VST

    Has anyone successfully gotten the iAquaLink 3.0 Controller to read and change the pump speed of a Pentair Superflo VST pump?
  13. pool light.jpg

    pool light.jpg

    Inground pool light
  14. T

    Is my Pentair Outdoor Wireless Transceiver Board Fried?

    I can't control control my system remotely through the ScreenLogic app. I suspect the outdoor transceiver board is fried. I'm not getting the Power (PWR) or Receiving (RX) to light up at all and the Transmitting (TX) LED rapidly flashes yellow. When I removed the cable from the board I...
  15. D

    Pentair Superflo VS 342001 pump causing frequency problem with salt generator

    My Pentair Superflo had a short in the feed that damaged the main board in my Jandy salt cell. Rewired pump and replaced board and everything works fine except whenever the pump is running the salt cell is not getting 60 Mhz and will not generate.
  16. P

    Creating a "Spa Low Jets" setting on Pentair Screenlogic 2

    Is there a way to create a circuit in Screenlogic that mimics the "Spa" circuit, but just has a lower pump rpm? Right now my Spa setting sets the jets to 3450 rpm and has lots of bubbles in the spa. Sometimes I'd like to keep the heat going and not have the bubbles. Ideally, I would create some...
  17. T

    Pentair Mastertemp 200 wont ignite.

    I'm currently servicing a heater for a customer that won't ignite. It will run through 1 cycle of trying to ignite, blower kicks on, gas valve opens, I can smell the gas but no ignition. The service heater LED comes on and then locks out the controls. The AGS light on the back of the control...
  18. wcmaness

    Can't Change Chlorine Output

    I have a Pentair system with an IC40 Intellichlor. Recently, my Intellichlor Load Center Surge Board went bad (partially) - so I've ordered a new one (but it's on backorder for an unknown length of time). The Intellichlor itself is still getting power and still works; but since the board...
  19. D

    Truclear SWG help

    My pump recently died and it was replaced with a Pentair VST pump. Previously everything was connected to a mechanical timer that turned everything on/off. The installer said since the new pump has its own timer I didn't need to use the mechanical timer anymore and he removed the on/off...
  20. L

    Thoughts on Pentair Laminars and Lights

    See signature for full build details. We demo'ed our old 16x32 vinyl pool but haven't started construction as of June 29, 2022. We really wanted to do 4x Hayward Laminars+ColorLogic 320's for our pool and stick with Hayward. However, supposedly Hayward laminars have been out of stock for months...
  21. D

    Leak Detection In Ground Pool with SPA and floor cleaners

    Hey Ya'll, Just bought a home. Guess what, Pool leaks. I got tired of filling pool daily so I let it leak to see how low it would go. It's about a foot below the skimmer and it finally stopped. The spa sits about a foot above the pool level and it is just below the spa jets. However on the pool...
  22. T

    Temperature Sensors w/ IntelliCenter

    Hi! Wrapping up the plumbing on a new install, and looking for some guidance on temperature sensors connected to our Pentair IntelliCenter. We have an i5 w/ IC40 Cell, UltraTemp 140, VSF, and some valve actuators for returns/features. I have to connect the solar temp sensor because of the...
  23. Joe Garcia

    Jacuzzi JVS 185S Above Ground Pool Pump...Simply Awesome from A-Z!

    My 10 year old single speed pool pump recently started to go south and I knew it was time for a change to a variable speed pump to save some money on my energy bill. Before my pump totally died I thought I should do some research on the main brands like Hayward and Pentair. I went to my local...
  24. Steve-D

    New to Pentair ScreenLogic

    Greetings all. We have a new build and Pentair came out yesterday to do the basic programming which was pretty much the last step in the installation. Surprise surprise, we can no longer control the pump at its controls (learned this is normal) and double surprise we learned that The Android...
  25. N

    IC40 with no lights

    Been a pool owner since 2019. The pool is fairly old, and I think the previous homeowners knew everything was about to die (not just the pool) and decided to sell. At opening 2020, IC40 worked fine at first, but then died (no lights). After some research, I determined it was probably beyond...
  26. S

    Replacing cut cables

    Both my communication cable for the pentair superflo vs and the aquacal temperature cable have been cut. That is why it hasn't been working. Is this something that I can fix myself? How do I figure out what cables to order? Any help would be greatly appreciated
  27. G

    Pentair Ultratemp 120 no heat!! Am I right????

    Hi All! Opened my pool for its second season. Haven’t gotten any heat out of my Pentair Ultratemp 120 Heat Pump. Only used for one northeast season. Pool was winterized by a professional company. Last season it worked great, heated the 10,000 gallon pool quickly and was even able to make it a...
  28. N

    Recommendation on how long and speed of pool pump

    Hi, I have Pentair VSP and I have been running for years at highest speed for 12 hours a day. I have also read somewhere that you can run at low pump, maybe at 1000 ppm. Is that right? With electricity cost nowadays, I hope I can save a few bucks here and there. What is your recommendation...
  29. A

    IC40 red flow, but replaced flow switch already

    Hello everyone. I have a pool I had built close to 5 years ago and a IC40 was put in. I havent had any trouble out of it until this year when I went to open my pool it shows a red flow light and the salt level is blinking between good and low. My assumption is the salt level reading isn't...
  30. R

    Brand New Pentair MasterTEmp 250 wont fire up

    Help. We replaced our previously blow Pentair MasterTemp 250 with the exact same model, thought 5 years newer, same plumbing same position everything and when we set it up exactly as is out of the box, it wont kick on. We have put a manometer to the test port on the outsdie the heater and...