Bypass Operation.
The heat pump may be controlled by a remote thermostat.
Disconnect power to the heat pump before removing any panels.
Use a proper outdoor rated 22 AWG cable (20 AWG for runs over 30 ft) for the connection from the thermostat to the heat pump.
Route the cable through appropriate knockouts making sure they are not shared with high voltage wiring.
Connect the thermostat cable to the “Remote On/Off” terminal.
After the thermostat cable is fastened and secure, refasten the panels.
Follow the steps on the next page to enable bypass operation.
Use the UP and DOWN keys to select bypass operation mode “0” (bypass operation disabled) or “1” (bypass operation enabled).
Once the desired modeis selected, wait 2 seconds for the selection to be saved.
NOTE: when bypass operation is enabled, the main interface will display “bo” and no heater operation will occur until bypass operation is disabled.
Parameter settings can still be changed.