Search results

  1. M

    Chiller?

    Yeah so it’s not like a chiller in hydroponics; you can’t set a temperature and it cools to that ?
  2. M

    2 Issues Blower and Pump

    HI, Background. My pool was stopped and drained for a remodel 3 months. 1) I have a blower that is connected to a pipe and returns to jets at the bottom of spa. My blower use to run 30 minutes then stop, now it runs 5 minutes and stops. The blower will not restart iaqualink reports it as...
  3. M

    PVC Pressure Testing

    Nitrogen water inline
  4. M

    PVC Pressure Testing

    All- My pump when spa mode is 23-28psi.
  5. M

    Blower Mod needed what’s the best solution

    I have two blowers for side jets and bottom. I want to be able to throttle the air throughput. I saw a post of Jandy 3way. Any other ideas what’s best have you guys tried this? What were results? Thanks so much tfp!
  6. M

    Plumbing Question for Heater (Jandy)

    Cartridge, I just replaced all four. I believe on heater 400000btu lxi in pic
  7. M

    Plumbing Question for Heater (Jandy)

    I just turned down my pump to 2000. I have a Jandy filter too, when the bypass is closed it goes right to fault hi limit so there must be too much water flow, I have heard of too little first time hearing too much. The pressure in spa mode is at 25 but pool mode around 12 Thanks guys!
  8. M

    Plumbing Question for Heater (Jandy)

    TFP Family- I had issues with Fault Hi Limit on my Jandy Heater. Im seeing this saftey configuration in the attached heater if I toggle the switch there is a sound of rocks in a pipe and fault hi limit. I believe this is routing some flow back to pool/spa without going to heater based on...
  9. M

    Filter Pressure with Variable Speed

    Its wasn't moving too much air from water low. Its good, was scared a second. I had to redo a bunch of things thought I messed something up. Thanks Jo!
  10. M

    Filter Pressure with Variable Speed

    Can someone tell me when I should see significant pressure on my Filter pressure when starting my pump. The pump primes at 3400 but not seeing filter pressure increase in first 10 seconds or so. My equipment was routed to detect a leak.
  11. M

    Leak at bottom of spa need **help please**

    Im not sure the function of the the bottom piece. The whole spa is finished but that piece. Looks like plaster crew missed it. There was hydroban I think the plaster crew missed this when they came through. That or it was intentional. This is the only unfinished area of the spa or pool.
  12. M

    Leak at bottom of spa need **help please**

    It was waterproofed have the pictures ywah I have the picture of the spa it had a gyroband after gunite. I’m thinking wet gunite from leak is giving gunite water to cause the problem so hopefully good now
  13. M

    Leak at bottom of spa need **help please**

    First thanks for fix and explanation. Answered exactly what I was asking. I did have one last question, on the repair how long should this sit. I can tell you I have a lot of efflorscense on the spa tile that is outward facing. Im thinking this water has the gunnite really wet as it was put...
  14. M

    Leak at bottom of spa need **help please**

    Thanks you I appreciate it!
  15. M

    Leak at bottom of spa need **help please**

    We had a lot of arguments with the builder they overshot the spa 2' and jackhammered. Just not a good experience, slow HOA complained. I ended up filling a BBB complaint but retracting during warranty period. They actually want to charge me as we had the pool less than 3 years but out of...
  16. M

    Leak at bottom of spa need **help please**

    I provided that 2nd picture your mentioning. Hard to see it dark. Here the pipe is on the side towards the bottom the sump pump is in the drain. The spa is slightly higher than pool it spills over to pool.
  17. M

    Leak at bottom of spa need **help please**

    The leak is 3/4 cm from the pipe and ran out for a long time slowly about 4" filling the bottom of the tub. If we didn't let it sit and loose water half the way it would have had more I believe
  18. M

    Leak at bottom of spa need **help please**

    Here this image might help. Dark out.
  19. M

    Leak at bottom of spa need **help please**

    My water stops by the fittings. However, I dyed the spa fitting and pressure tested. There is no leaks there. This looks like mostly raw exposed gunnite there is no plaster or tile. I see my spa drain at night when I awake down a few inches it actually leaks into the gunite spa
  20. M

    Leak at bottom of spa need **help please**

    It poured out of a whole about 3/4 centimeter from the pipe where it is black. It filled it up the bottom of the spa 3-4" when it ran out for 2-3 days maybe more, I needed to use a sump pump. Im trying to figure out why it isn't plastered or tiled. This black stuff looks like paint. Cant...
  21. M

    Leak at bottom of spa need **help please**

    All- We had a slow leak with this pipe at bottom of spa. It was covered by a grate. I can't see that the builder did much to seal this, can someone look at the photo in Pool Business and comment on what they see the rest of my spa is tile but need comment on the solution or lack there of one...
  22. M

    Pool Leaking

    I found both leaks first was infiniti wall tile crack leak and 2nd was a circle pipe 1' in circumface with fitting over that was plastered or sealed.
  23. M

    Pool Leaking

    So I found the leak the tile ontop of negative edge has water coming under, a five foot section is barely holding on. I let is train the 12" of tile across the edge peeling away. This pool isn't three years old. I still have my spa draining, the check valve was bad I replaced it. Still...
  24. M

    Pool Leaking

    Thanks I had it all in not sure what happened.
  25. M

    Pool Leaking

    I have a raised infinity spa which flows into an infinity pool which flows into a catch basin. Water is circulated from Catchbasin up to a feature pump which sends back to spa and pool returns. Every night my pool raises water 5" and pool water would go out overflow. Spa goes down a few...