Caretaker Ultra Flex 2 Tripping Circuit breaker

Welcome to TFP.

This manual does not show a circuit breaker inside the control box - https://www.zodiacpoolsystems.com/-/media/Zodiac/Global/Downloads/TL/TL-1300.ashx

Confirm the CB is in the control box and not in your circuit breaker panel.

Post pics of the breaker that is tripping.
Welcome to TFP.

This manual does not show a circuit breaker inside the control box - https://www.zodiacpoolsystems.com/-/media/Zodiac/Global/Downloads/TL/TL-1300.ashx

Confirm the CB is in the control box and not in your circuit breaker panel.

Post pics of the breaker that is tripping.
9FA9C521-B0C0-4DBD-ACD0-1B5BD11A7A8E.jpeg
 
Ok, I see the reset on the 24V secondary side of the transformer now.

I would suspect that there is a problem with the motor causing the breaker to trip. The motor is the only thing drawing power.

 
Welcome to TFP.

This manual does not show a circuit breaker inside the control box - https://www.zodiacpoolsystems.com/-/media/Zodiac/Global/Downloads/TL/TL-1300.ashx

Confirm the CB is in the control box and not in your circuit breaker panel.

Post pics of the breaker that is tripping.
Welcome to TFP.

This manual does not show a circuit breaker inside the control box - https://www.zodiacpoolsystems.com/-/media/Zodiac/Global/Downloads/TL/TL-1300.ashx

Confirm the CB is in the control box and not in your circuit breaker panel.

Post pics of the breaker that is tripping.
View attachment 128662
Ok, I see the reset on the 24V secondary side of the transformer now.

I would suspect that there is a problem with the motor causing the breaker to trip. The motor is the only thing drawing power.

Thank you very much! I’ll start with replacing the motor. It’s 15 years old and “chirps “ when rotating.
 