Hello. I lurk here occasionally, and tbh, wish I'd checked here before building my pool last year, but I didn't, so here we are!
I have an Pentair Ultratemp 120 H/C heatpump (heat/cool) that is acting very strangely. I'm in Texas, trying to heat my spa currently. I have it set to 104. It runs for about an hour, and then stops. The temperature this brings it to is inconsistent, and seems to have more to do with ambient temperature than anything else. Following that (without changing settings) it begins rapidly cycling. It seems to try to start and then fail. The best way to understand the problem is to view the "history" screen from Screenlogic ("solar" is what Pentair uses for heatpumps):

With this chart, we can see it's not shutting off because of the ambient temperature (It turned on at noon, ran until 1:19, during which time the ambient temperature went up). The water temperature at 1:19 was 94. Testing at different times, I've had it shut off at a different temperature (eg. 88), so it's not related to the actual temperature - it doesn't think it's hit 104. And you can see once it starts rapid cycling, it no longer heats. If I try to run it several hours later, it runs for a much shorter time at the beginning (I tried running it just after 9 pm - it ran for 6 minutes before rapid cycling. And it is VERY rapid cycling and not consistent. Here it is during a 4 minute period:

Anyone seen anything like this before and/or have any ideas?
I haven't yet called Pentair or my builder (incompetent), and I can't find anything that matches this pattern in the manual. I wondered if anyone here had seen it before calling Pentair.
I have an Pentair Ultratemp 120 H/C heatpump (heat/cool) that is acting very strangely. I'm in Texas, trying to heat my spa currently. I have it set to 104. It runs for about an hour, and then stops. The temperature this brings it to is inconsistent, and seems to have more to do with ambient temperature than anything else. Following that (without changing settings) it begins rapidly cycling. It seems to try to start and then fail. The best way to understand the problem is to view the "history" screen from Screenlogic ("solar" is what Pentair uses for heatpumps):

With this chart, we can see it's not shutting off because of the ambient temperature (It turned on at noon, ran until 1:19, during which time the ambient temperature went up). The water temperature at 1:19 was 94. Testing at different times, I've had it shut off at a different temperature (eg. 88), so it's not related to the actual temperature - it doesn't think it's hit 104. And you can see once it starts rapid cycling, it no longer heats. If I try to run it several hours later, it runs for a much shorter time at the beginning (I tried running it just after 9 pm - it ran for 6 minutes before rapid cycling. And it is VERY rapid cycling and not consistent. Here it is during a 4 minute period:

Anyone seen anything like this before and/or have any ideas?
I haven't yet called Pentair or my builder (incompetent), and I can't find anything that matches this pattern in the manual. I wondered if anyone here had seen it before calling Pentair.