Recent content by ps0303

  1. ps0303

    Heater display/controls inoperative

    Most likely you have a bad display module. However, depending on where you live, it could be a tree frog that go in where the board is and got fried. I would remove the board and look at it and if you see signs on a frog dead on the board, you might need a new board which comes with a new...
  2. ps0303

    Pentair Ultratemp Hybrid heater with Jandy Aqualink

    Out of curiosity, why are you considering the Ultratemp ETi hybrid heater?
  3. ps0303

    This Frog Had A Very Bad Day.....

    Yup I see this a lot here in Florida. Use some duct tape to cover the holes that allow the critters to inside where the board is located. Also, Raypak does have a foam piece that they gave some installers and it goes between the board and the bezel to protect it. You'll have to call them for the...
  4. ps0303

    Pentair Mastertemp 400 Problems

    Make sure that you are noting having an issue with your automation temp sensor. People tend to overlook that and think it's a heater problem. So look to see what the automation says your current water temp is. Also, you need to check for continuity on the wire between the heater and the...
  5. ps0303

    Jandy JXI 'Check Flow' Issue

    To run that heater efficiently, you really need to have the pump speed higher. 2700 - 3000 rpm while the heater is in use per the manufacturer. Filter cartridges should be cleaned once a month or so. Do not rely upon your filters pressure gauge to tell you that the filter needs to be cleaned...
  6. ps0303

    Conversion kit for Hayward h2001

    You'll also need to convert the gas valve or get one that is set up for propane.
  7. ps0303

    SOLVED! Pentair MasterTemp 250 Error E01 - 126 -Not the Thermistor...

    Well if Pentair diagnostic says "replace board", then replace the board. Try not to over think things.
  8. ps0303

    Mastertemp 400 intermittently working/not working

    Bad blower motor or bad run start capacitor if so equipped. Post a picture of the motor.
  9. ps0303

    Cracked Manifold

    This is an informational post. What can happen if a pressure relieve valve fails? This will happen.
  10. ps0303

    Plumbing for heater

    Yes put the heat pump before the gas heater.
  11. ps0303

    H250 gas regulator fail?

    If the gas valve is working, you should smell gas when it opens and tries to light. If you don't smell gas, you have a gas flow issue.
  12. ps0303

    Raypak M266A Main Ign Failure

    Yup I see the frogs here in Florida on many of the Raypak/Rheem boards. Raypak did come out with a high density foam panel that you can sandwich between the board and the bezel to keep these frogs out. Alternatively you can use some good duct tape and cover over all the holes inside the unit...
  13. ps0303

    Pool leaking 2 inches a day

    Pool leaks can drive you crazy. Spend the money and hire a leak detection company to come out and do a complete run thru of your system. It is well worth the price of admission. I know this from personal experience and I'm in the pool business.
  14. ps0303

    New Pentair Mastertemp 125 Heater Installation - Squeals like a pig when heating...

    Companies are tired of wasting time and money for DIY installs. BTW, I wouldn't be surprised if more companies stop allowing their units to be sold on the internet. It's not like buying a refrigerator and plugging it in to power. I can't begin to tell you the number of times a homeowner...
  15. ps0303

    Max-E-Therm Automation Wiring Shorted

    birdman579 You need to put mesh wire over the vents on this unit to keep the mice out. There is a company that sells pre-cut mesh panels exactly fort his heater. I am not associated with the company, Products | MK Rat Proofing, that makes them but I have used them on several of my customers...