ps0303
Featured content
0
Reaction score
40

Joined
Last seen

Latest activity Postings Media About

    • ps0303
      ps0303 replied to the thread Jandy JXI400N - Trouble Air.
      Honestly, it's not worth the price. I have never seen all brass fittings like that in the field ever.
    • ps0303
      If the blower motor is not coming on, you'll get an air flow fault. When the unit operates normally, when you turn it on the system...
    • ps0303
      ps0303 replied to the thread Raypak M266A Main Ign Failure.
      When looking for a sooted heat exchanger, you have to do more work to really see it. You can pull the burner tray and stick your head up...
    • ps0303
      ps0303 replied to the thread Raypak r406a won't spark.
      If you can't hear the spark by the igniter, then it's most likely a bad board. If you can hear the spark but no ignition it's either a...
    • ps0303
      ps0303 replied to the thread Jandy JXI400N - Trouble Air.
      PRV's are a 50/50 in the field. And when they are used, it is connected with galvanized pipe always. Out of the PRV people do use PVC...
    • ps0303
      Try this, clean the pool very well so you don't see any dirt. Then for the next 24hrs, leave the pump off and see if you get any dirt in...
    • ps0303
      Very good. Good luck with Hayward. Their folks usually don't have that info.
    • ps0303
      ps0303 replied to the thread Jandy JXI400N - Trouble Air.
      If the can was full of water, it's a leaking heat exchanger. Highly doubtful that the metal plate is warped. I've never encountered one...
    • ps0303
      ps0303 replied to the thread Jandy JXI400N - Trouble Air.
      Well something in the water quality caused this to leak in those 5 years.
    • ps0303
      So there are some differences between your old pool and this one. One being the raised beds with plants in them on the new pool. Also...
    • ps0303
      ps0303 replied to the thread Jandy JXI400N - Trouble Air.
      5 years is pretty young for this issue. I know you say the chemicals are spot on since it was built but a heat exchanger fails 99% of...
    • ps0303
      Did you have plants around your old pool like this one has?
    • ps0303
      ps0303 reacted to JamesW's post in the thread Jandy JXI400N - Trouble Air with Like Like.
      This is exactly why no service person would do a rebuild. You spend more than a thousand dollars on parts and 10 to 20 hours on labor...
    • ps0303
      ps0303 replied to the thread Jandy JXI400N - Trouble Air.
      BTW, do you have pictures of the current heat exchanger showing the end of the tubes as they exit the plate they are attached to...
    • ps0303
      ps0303 replied to the thread Jandy JXI400N - Trouble Air.
      I wouldn't charge anything as I would not do that job. I will sell you a new unit or you will have to find someone else willing to spend...