    Power connection to a v green

    I was planning on using the digital inputs using the 12vdc from the rs 485 jack. I would then take the +12v to the EasyTouch and the use the spare relays to control the speed. May need to add some relays if I don't have enough. Any other thoughts on using the digital inputs would be nice.
  2. M

    Power connection to a v green

    I will not be using the RS 485. The interface is too expensive and I don't know if it compatible with the EasyTouch.
  3. M

    Power connection to a v green

    I just purchased a V green 240v motor. Starting to connect it to my Pentair EasyTouch panel. Do I still use the pump relay circuit from the EasyTouch or do I connect it directly to a 240v breaker? If I use the EasyTouch relay to power to the pump, the power will be gone when it turns the...
  4. M

    Paramount water valve

    The balls are inside the housing. They are not acrylic. They are just little balls about 1/4" that cover a hole. When I put the gear assembly into the valve all of the heads are up. What makes the heads go down? The 6 white discs on the bottom of the gear assembly are loose and go up and...
  5. M

    Infloor pool cleaners

    I have a Paramount pool cleaner that is not working. Was thinking of changing to an A&A because of the availability of rebuild kits. Is this worth it? Will the six ports align wit h my existing six pipes?
  6. M

    Paramount water valve

    No, it is the older model. Sorry it took so long to reply, was out of town.
  7. M

    Paramount water valve

    I have a Paramount 6 port water valve that is not working. Took out the gear module and all looks fine. Removed the gear collar and found 6 balls covering 6 holes. How does this thing work? I see a cam that pushes the ball off the hole. Is there supposed to be some sort of gasket over these...
  8. M

    Aux valve A

    The valve moves 180 degrees to the other position
  9. M

    Aux valve A

    I'm trying to setup aux valve A to operate my solar panel diversion on an easytouch. I have everything connected but I cant get the valve to rotate to bypass. I have solar enabled in the panel but I only get power on the black/white wires. Weather on Spa or pool the power is always on the...
  10. M

    Solar panels

    Thanks for the info. I do have a vacuum breaker near the top.
  11. M

    whisperflo performance curve

    Found my answer on Pentair site. Looks like I have the standard version. Thanks
  12. M

    whisperflo performance curve

    how do I know which one I have? My pump is Part # 011773 dated 10/21/2013.
  13. M

    Solar panels

    New pool owner in Florida. I am a snow bird, about 5 months in Florida. I have solar panels on the roof. Is it OK to fully bypass the panels in the summer when I am not there . Or do they need water in the hot sun?
  14. M

    whisperflo performance curve

    I noticed that the whisperflo curve in the user guide is different from the whisperflo curve I get online (inyo & others). Did Pentair change there calculation method or is it something else?
  15. M

    mastertemp 250 with easytouch

    Just replaced pool control with an easytouch PSL4. Old system had heater connected with 3 wire system. I will connect with 2 wire from J19 to mastertemp firemans switch. Question I have is do I need to be concerned about the jumper setting on the operating control board (external control...