Yep, I can see that getting pulled up by the pump. Double checked the lid was tight, and the union before the pump has an o-ring. Gonna try again and then check the union from the pipe direct to the pump, though it wasn’t taken apart.Did you fill the volute with water?
Yep, did that. I’d think if it was something in the pump it would leak out the water I put in it to prime instead of not priming….Lube all the o rings with silicone. Lid, both pump drain plugs and union. Make sure drain plugs are in and tight.
Won't make any difference.Hmm. What if I close my water inlet from the pool, and put water down into the top of the pump to fill it from that end?
Wouldn’t it show if there’s some sort of leak on the pump itself? What in the pump would cause it to not prime if the lid is sealed, plugs are in, unions on suction side are secure?Won't make any difference.
Pressure testing a pump can be dangerous, lid can blow.Wouldn’t it show if there’s some sort of leak on the pump itself? What in the pump would cause it to not prime if the lid is sealed, plugs are in, unions on suction side are secure?
There’s only two unions before the pump, and both were checked at least three times. Pump lid checked and lubed again. Unless my jandy valve started leaking, not much else to check. :/There is a suction side leak. Go through it again. Clean the orings for any dirt, clean the mating surfaces, relive again. This happened to me too.