- Jul 8, 2021
- 6
- Pool Size
- 25000
- Chlorine
- Salt Water Generator
- SWG Type
- Hayward Aqua Rite (T-9)
I have a T-9 cell and after calibration the salt level reading is still showing way lower than the actual salt level in the pool. Only after changing the cell type in the menu from T-9 to T-5 the salt level goes up from 2000 to 3000 and the cell works again. In the menu > cell type (t-9) > move the switch to super chlorinate and back until it shows 1 type lower (T-5) cell.
This is not ideal because the chlorine output is lower, but not bad for the cell because the power input for the cell is also lower.
Is there be a better solution to 'repair' the cell?
Since there is no salinity sensor in the cell and the salinity level is measured in relation to conductivity and temperature (red and blue wire). What if the resistor of the temperature sensor is changed how much would this affect the salinity level? and should the resistor value be higher or lower?
This is not ideal because the chlorine output is lower, but not bad for the cell because the power input for the cell is also lower.
Is there be a better solution to 'repair' the cell?
Since there is no salinity sensor in the cell and the salinity level is measured in relation to conductivity and temperature (red and blue wire). What if the resistor of the temperature sensor is changed how much would this affect the salinity level? and should the resistor value be higher or lower?