  1. G

    Aquarite only has power light on, all others off

    A few years ago I'd replaced the thermistor. I wicked off the old solder and inserted the leads of the replacement into the PC board and with some difficulty soldered it in place. A few weeks ago I had the power light on but nothing else cited above. Following the troubleshooting chart I...
  2. G

    Experiences with SWGs other than Hayward's Aqua Rite

    I've just repaired the main circuit board on my Aqua-Rite SWG for the second time with absolutely no technical help from Hayward. Do any members have experiences with other makers they'd be willing to share? If I switch makers at some point I'd naturally perfer one with a cell which would...
  3. G

    Bad main circuit board? Dealing with Hayward??

    Acting on a hunch I reheated the solder connections I'd made several years ago to the thermistor. A "cold" solder joint can function properly for quite a while, then either fail completely electrically or become intermittent. Generally a cold joint will look sort of granular, rather than...
  4. G

    Bad main circuit board? Dealing with Hayward??

    I am dealing with a probable circuit board failure on my Aqua Rite generator. All was well until a few days or so, but then ... no LEDs, or LCDs. On power up after the flow was established I'd get a brief display of LEDs indicating chlorination and inspect the cell, then nothing. I followed the...
  5. G

    Aquarite light come on then go off

    I am dealing with a probable circuit board failure on my Aqua Rite generator. All was well until a few days or so, but then ... no LEDs, or LCDs. On power up after the flow was established I'd get a brief display of LEDs indicating chlorination and inspect the cell, then nothing. I followed...
  6. G

    Possible bad salt cell??

    Many thanks to all for the help! The pool is improving with the aid of lots of bleach. JamesW, I apologize for omitting the datum of green water! Somehow I had thought that would have been self-evident. It would be nice if the Cl test in the Taylor DPD kit had a more easily discernible...
  7. G

    Possible bad salt cell??

    I've never used any algae treatments with copper salts; they would plate out on the cell plates and ruin them. No ascorbic acid. As far as hydrogen bubbles from the returns the water is too green to tell! If it is working and making chlorine, why didn't any show in the water taken from the...
  8. G

    Possible bad salt cell??

    Just now I loosened the union downstream from the cell as it operated and collected a water sample. No discernable chlorine. Here are data from the diagnostic panel: Salt level display 3000 88F 25.2 v 6.34 a 100% 2900 inst salinity Change polarity 88F 25.1 v 6.49 a 100% 3100 inst salinity...
  9. G

    Possible bad salt cell??

    I will certainly try that. I'd tried it with the old cell, and measured essentially zero chlorine, despite good data from the diagnostic panel.
  10. G

    Possible bad salt cell??

    the old cell instant salinity was 2900 or 3100 depending on cell polarity, on 7/13. The new cell arrived on 7/15, was installed immediately and gave instant salinity of 2700 or 2800, depending on cell polarity. "New cell's instant salinity depending on polarity is 2800 or 3000, taken this...
  11. G

    Possible bad salt cell??

    Thanks for your response. As stated above, on 7/13 If it is generating the correct amount of Cl, why was the Cl essentially zero at 7.30 am this morning? I would have expected some Cl since there was no sunlight to burn it off, and the CyA is adequate. Okay, I'm putting 6 121 oz jugs of 6%...
  12. G

    Possible bad salt cell??

    I'm using the Leslie's Deluxe Poolcare DPD Test Kit, made by Taylor. I bought it in June of this year; I don't trust strips. The old cell's instant salinity varied between 2900 3100, taken on 7/13, depending on cell polarity. New cell's instant salinity depending on polarity is 2800 or 3000...
  13. G

    Possible bad salt cell??

    Thanks for that info.
  14. G

    Possible bad salt cell??

    Well, I tested the water this morning at about 7.30AM. Chlorine essentially zero after the SWG ran all night at 100%. pH 7.6 Cya 70 Cl essentially zero Total alkalinity 80ppm Readings off the diagnostics, second column is reversed polarity. Displayed salt level is 3000. Temp 87...
  15. G

    Possible bad salt cell??

    Interesting! Perhaps despite the readings off the controller my cell is problematic. I've ordered a new cell...its only money, and a pool is much cheaper than a boat!
  16. G

    Possible bad salt cell??

    After running all night at 100% Cl is essentially zero. Salt on the controller indicates 2900 ppm. I took a water sample by Leslie's and their electronic salt meter indicated 2800 ppm. Yesterday the Taylor salt test indicated about 5000 ppm. CYA is still low, about 30 ppm. Values on the...
  17. G

    Possible bad salt cell??

    Flow switch is new. Instant salinity varies between 1900 and 2000. I'll do the 24 hour thing and see what happens.
  18. G

    Possible bad salt cell??

    Okay, the cell tested OK at Leslie's. I bought it in May of 2015, so it should still be good. The generator ran fine all day yesterday, indicated salt level 2800. This morning the salt level indicated 2600, check salt and inspect cell both flashing, generator running. I'd received my Taylor...
  19. G

    Any opinions on this book?

    Is this worth $24.00, or does this forum have all the information, albeit in some what less convenient form? The Complete Guide to Salt Water Pools
  20. G

    Possible bad salt cell??

    Well, with the help of this group I diagnosed and replaced the thermistor on my AquaRite. All was well, salt level at 3200. Now....the salt level is rapidly dropping, according to the display. It showed 2900 yesterday, 2100 this morning, and 2000 just now. There used to be telephone help...
  21. G

    AquaRite generator not generating!

    Okay! I reinstalled the board, and while frantically stroking a rabbit's foot (the rabbit was NOT amused!) waited for the no-flow light to go out. Eureka! All systems go!:kim:It's been pumping chlorine for the past two days. I did have the good sense to put the extra thermistor of the two...
  22. G

    AquaRite generator not generating!

    Okay, I've pulled the board, making notes as to what color wire goes where. The thermistor has a crack on one side, and the PCB is somewhat discolored where the thermistor is soldered in. Naturally I couldn't find my electronics tool box with the solder sucker and solder wick, so I'll make do...
  23. G

    AquaRite generator not generating!

    Okay. On power up the no-flow LED glows. After 15 or 20 seconds flow starts, the check cell light illuminates briefly - then nothing! No indicators at all. I've just cleaned the cell w. HCl in the recommended fashion, no go. After 45 minutes on hold with Hayward I find that they don't have...