Search results

  1. T

    Intelliconnect and color led?

    Anyone use an Intel connect relay to run a color LED? When you set it up you have the option of Pentair, Jandy, or Hayward led which I’m assuming controls how many times it needs to cycle the power to get to a specific color. My main problem with my color LED has been the color changing...
  2. T

    Replacing Maytronics Cord - Active 20

    I’ve ordered a new cord assembly with swivel for my active 20 robot, the DIY part number matching the current end. The robot end of the cord the plug seems to be coated with some sort of dielectric grease to help keep water out. Will the new one come with this grease, or do I need to provide...
  3. T

    Pentair Cartridge - Input Union

    With a new pump I need to redo all pipe between my pump output and filter input to change the pump position. I'm looking at getting a new union for the filter inlet, it looks like there are four parts there based on the parts diagram here - Clean & Clear Do I need to replace all four, or just...
  4. T

    Need new pump - Intelliflo right for me?

    I need a new pump. My pool is 18k gallons. Two skimmers, 1 main drain. 3 1.5 suction lines running to the pad. Two 1.5 return lines running back to the pool. I plan on adding a water feature in the future. Pentair clean and clear 200 cartridge filter. What I'm looking at doing is replacing my...
  5. T

    Transition from 1.5" to 2", suction side

    I have three 1.5" runs coming back from the pool on the suction side, two skimmers and a main drain. I have to re plumb the suction side of the pump due to the crappy red handled PCV valves on each supply. I have three 1.5/2 neverlube valves. The pump is a Pentair WFE-4 with a vGreen 1.65...
  6. T

    Red brick coping , liner pattern?

    Anyone have a liner that they love with a red brick coping? I looked through the photos section, but really only found one with a red brick coping. Getting ready to pick a new liner, looking for pattern recommendations that work well with red brick.
  7. T

    110v Variable Speed Replacement for Pentair WFE-4?

    I have a Pentair WFE-4 wired at 110v. I was going to order the Centruy V-Green 165 replacement motor, but it is 230v only and i'm currently 110. It looks like my only 110v option is to replace the entire pump with a Pentair Superflo VS which looks to be dual 110/230v. Is this a good replacement...
  8. T

    Putting in an offer on a house, replaster and waterfall stains?

    Putting in an offer on a house, it has a dark plaster free form gunite pool with a "spa like area" that isn't a spa. Single return in the spa area, no jets and no heat. Equipment is a cartridge filter, salt system, ozone system, and fixed speed pump. The plaster is 10 years old and starting to...