Standalone vacuum pump

Sidemoves

Gold Supporter
Bronze Supporter
Jul 26, 2022
243
Fairfax, VA
Pool Size
37500
Surface
Plaster
Chlorine
Salt Water Generator
SWG Type
Pentair Intellichlor IC-60
Hey all- want to get a standalone pump to run the vacuum and for draining water at closing. Any suggestions? Thanks in advance!
 
Is it worth spending $699 on that pump? Or should I go for something cheaper like this?
Cool I’ll give it a try. Not really expecting to use it more than 2-3x per year. Cleaning at opening and drain water at closing. And maybe an occasional cleaning mid season. So hopefully I can get 2-3 years out of it.

Unless you have a different suggestion for a decent cheap pump?
 
Cool I’ll give it a try. Not really expecting to use it more than 2-3x per year. Cleaning at opening and drain water at closing. And maybe an occasional cleaning mid season. So hopefully I can get 2-3 years out of it.

Unless you have a different suggestion for a decent cheap pump?
That above-ground pump from Doheny's may, or may not, self prime. That's the biggest issue with using that type pump on a port-a-vac. Also, whatever filter you are using will have to be cleaned more often with an above-ground pump as they just can't push that well against a dirty filter. Doheny's has a 1hp in-ground pump for only $140.00 more. If you plan on using your system much, you'll find that it was worth it.
 
  • Like
Reactions: Sidemoves
That above-ground pump from Doheny's may, or may not, self prime. That's the biggest issue with using that type pump on a port-a-vac. Also, whatever filter you are using will have to be cleaned more often with an above-ground pump as they just can't push that well against a dirty filter. Doheny's has a 1hp in-ground pump for only $140.00 more. If you plan on using your system much, you'll find that it was worth it.
Thanks for this advice! Are you suggesting I should be using a filter for the port-a-vac?
 
Thanks for this advice! Are you suggesting I should be using a filter for the port-a-vac?
If you don't want to throw large amounts of water down a drain when vacuuming, use it with a cartridge filter. For draining, just remove the cartridge.
I only had a setup with a filter for a short while, then gave it to a friend. Didn't work for my purposes. If the pool was so dirty that I had to bring in a separate pump, the debris went onto the ground or into a sewer. It was a setup as in ajw22's photo. I also had a portable gfci that was plugged into an out let then the pump plugged into it.
Was only used on commercial pools, which are usually larger than residential, as the amount of water that you can pump through an open line can quickly drop a residential pool below the skimmer. Then you sit there and watch a pool fill or risk flooding a customer's property ("No you didn't tell me the water was running!") or damaging their equipment from running dry ("You didn't tell me the pool needed to be re-filled!").
 
  • Like
Reactions: Sidemoves
Any inexpensive 3/4 HP single speed pump wired to a 120V plug in power cord will do.

View attachment 563020
Thank you @1poolman1 and @ajw22 for the advice. I ended up going with the more expensive 3/4hp Hayward. Do you by chance have links to the fittings /hose you used to attach to the in/out sides of that pump?
 

Enjoying this content?

Support TFP with a donation.

Give Support
  • Like
Reactions: Sidemoves
Mine didn’t come with an outlet or cord pre wired. Have to do that myself apparently haha
Get a good 50' or 100' outdoor extension cord. Cut off the female end and use the wires for the pump. Gives you a waterproof plug.
Its best if you can use crimp-on wire terminals. 1714076716041.png
Use a strain-relief bushing like this from Home Depot to keep the cable in the motor:
1714076572197.png
 
  • Like
Reactions: Sidemoves
ok so I got it all wired up. But can’t seem to get it to actually pump water. I’ve tried priming the pump and the hose. Made sure all the connections have a good seal. Applied a little silicone to the plugs. But still not pumping water. When I prime it, it will pump that water through but then just goes empty pretty much.

I’m using 40 ft hoses on both ends - vacuum and discharge. The only thing I can think of is maybe the pump is underpowered for the length/run of the hoses? But not sure that’s the issue.

Any advice would be appreciated

IMG_9667.jpeg
 
Sure sounds like a suction side air leak.

The pump cannot be underpowered for the hoses.
 

Enjoying this content?

Support TFP with a donation.

Give Support