I'm planning on starting the construction of a pool with flush spa during the upcoming weeks. The current plan is to use a single Intellifo3 pump and Intellichlor SWG for the water circulation/chlorination. The attached diagram shows the planned pool/spa piping and valve diagram. One of the Intelliflo3 relays will be used to switch between Spa and Pool mode (energizing the diverter valves actuators), the heater will be manually switch on at this point. The system will consist of 6 pool returns (one of them inside the Spa) and 6 spa venturi jets. When in pool mode the return inside the Spa should circulate and chlorinate the Spa water forcing spa overspill, when in Spa mode the water should circulate and heat the spa water only.
I would appreciate your feedback on the following:

I would appreciate your feedback on the following:
- Is it appropriate to install one pool return inside the spa to circulate spa water while in pool mode?
- Is a Pentair Intelliflo3 3HP pump appropriately sized for 6 spa water jets? No spa blower is currently planned.
- Can the Intelliflow3 control the Intellichlor output % from the selected program? The plan is to use the RS485 comms in standalone mode to communicate with the Intellichlor SWG cell (no further automation is planned at this point).