Recent content by jubjub

  1. J

    New Gunite Pool Leaking / Stained

    Ouch? How did it get resolved? Re-plastering?
  2. J

    New Gunite Pool Leaking / Stained

    Thanks, I already have the PB looking at it as we speak. I'm just looking to arm myself. I haven't been completely satisfied with their quality of work and communication.
  3. J

    New Gunite Pool Leaking / Stained

    Unfortunately, I didn't think to take thorough pics before the plaster was poured. I watered it daily, but only took this pic that probably isn't very helpful.
  4. IMG_5390.jpeg

    IMG_5390.jpeg

  5. J

    New Gunite Pool Leaking / Stained

    Our new gunite pool just finished late last week with it being filled with water on Fri. We have a pool leak (have lost over 3 inches in less than 24 hours). I took photos of the plaster before it was filled with water. I was assuming the discoloration would blend in over time with daily...
  6. IMG_5440.jpeg

    IMG_5440.jpeg

  7. IMG_5439.jpeg

    IMG_5439.jpeg

  8. IMG_5438.jpeg

    IMG_5438.jpeg

  9. Pool Streaking.jpg

    Pool Streaking.jpg

  10. J

    Need Advice: Mastertemp 400 Control Board Fried? (See pic)

    The Fenwal flashed 3 times, which means ignition lockout. That's when I replaced the igniter and the Fenwal. Like I said, I thought that would have fixed it, but it was the regulator that did the trick. I am curious if you have any theory as to what was the actual cause.
  11. J

    Need Advice: Mastertemp 400 Control Board Fried? (See pic)

    I ended up replacing the igniter with no improvement. I then replaced the Fenwal with no improvement. I finally replaced the thermal regulator, which did the trick. I'm happy I bought a used $30 Fenwal on eBay instead of paying ~$170 for a new one. Thanks to all who weighed in on suggestions...
  12. J

    Need Advice: Mastertemp 400 Control Board Fried? (See pic)

    No water came out. They do look rusted, but no water.
  13. J

    Need Advice: Mastertemp 400 Control Board Fried? (See pic)

    Is there a walkthrough you can refer me to on how to check the ignitor?
  14. J

    Need Advice: Mastertemp 400 Control Board Fried? (See pic)

    So, my Mastertemp 400 NG heater (built in 2010), which we rarely use here in FL, ignites, but then 3-4 seconds later shuts off and triggers a "Service Heater" light. I flipped the board over and did not observe any additional error lights. FWIW, the thermal regulator has a lot of corrosion...
  15. 012b9a35131ffac0d516f877a913454a4eac59495f.jpg

    012b9a35131ffac0d516f877a913454a4eac59495f.jpg