RM,

Thanks for the great screenshots... :goodjob:

You have a PSL4, which is a 'lite' version of the EasyTouch.

It can only have 4 schedules max, including any egg-timers not set to the default of 12 hours.

You have 6 schedules..

Unfortunately, ScreenLogic will let you add a bazillion schedules, they just won't work.

As a side note.. If wired correctly, your SWCG will only run when in the pool or spa modes.. This means that when you are in low speed, the cell will not work..

Thanks,

Jim R.
 
RM,

Thanks for the great screenshots... :goodjob:

You have a PSL4, which is a 'lite' version of the EasyTouch.

It can only have 4 schedules max, including any egg-timers not set to the default of 12 hours.

You have 6 schedules..

Unfortunately, ScreenLogic will let you add a bazillion schedules, they just won't work.

As a side note.. If wired correctly, your SWCG will only run when in the pool or spa modes.. This means that when you are in low speed, the cell will not work..

Thanks,

Jim R.
Much appreciated Jim! I will set all egg timers to 12 hours and remove the low speed.

Thanks!
 
RM,

The basic concept for running an EasyTouch is to set your Pool Circuit to the lowest speed you ever want to run.. Then use Feature circuits to increase speeds. When the pump sees two or more speeds at the same time, it will always run the fastest one.

Thanks,