I'm posting my issue for confirmation. I'm pretty sure what the problem is. I was testing the FC in the pool water this evening. It was low even though I had recently increased the output. I looked at the cell. The red cell light was on. On the display, it read COLD. In diagnosis mode, the cell is reading the water temperature as 45F. The real temperature is 87F. This indicates to me that the thermistor on the flow switch has failed. I'll need to replace the flow switch.
Is that right?
Is that right?