- Jun 24, 2021
- 15,913
- Pool Size
- 29000
- Surface
- Vinyl
- Chlorine
- Salt Water Generator
- SWG Type
- CircuPool RJ-60 Plus
Low. It does happen, but it wouldn't drive variation between tests, it would drive variation from actual.What are the potentials for variation between "batches" of testing reagents from TFTestKits?
My vial from last year is blackish and it has been working fine.And I've read that blackish powder and chunky is ok to use if you break it up, but the new one is pure white and not chunky.
What are the potentials for variation between "batches" of testing reagents from TFTestKits?
Exactly right. I wondered if that took a sec to sink in…seems a batch shift to me.Ok, I didn't track that. So test 1 and 2 were old and 3 and 4 were new?
Ive never seem black powder and Ive got powder close to 2 years old (it does look slightly grey) I wouldnt trust it even if its supposed to be ok.I understand, but what I'm trying to reconcile is that the new powder and drops were consistent on 2 tests back to back without cleaning. That's great...but much lower FC and variable CC than the slightly older powder and drops.
All I can do is pitch the older stuff since I don't trust it and continue with the new to prove it out further.
What are the potentials for variation between "batches" of testing reagents from TFTestKits? And I've read that blackish powder and chunky is ok to use if you break it up, but the new one is pure white and not chunky.
purchased from TFT in Feb this year. I keep it inside in a cabinet, closed up etc. I hope it doesn't degrade that fast? Regardless, moving on with the newer stuff.Not a batch shift, the older reagents are degrading...hence higher FC result (more drops because not as strong).
Odd. I guess I should have asked how "old" old is...figured it was a year or more. Next time I'll ask.purchased from TFT in Feb this year. I keep it inside in a cabinet, closed up etc. I hope it doesn't degrade that fast? Regardless, moving on with the newer stuff.
cover has been not been shut, ~1/4" of rain yesterday, plenty of wind & airborne stuff but swept out & skimmer kept clean. Water is crystal clear. 50 CYA SLAM FC maintained at 20-22 throughout the day. OCLT info below. I took two tests back to back from same sample bottle for trying to build my confidence in the repeatability of the tests. Believe me, I'm being as meticulous and consistent as I can in measuring, process etc...particularly with vertical bottle, slow drops and 10mL to the bottom of the meniscus, using a small dropper.
5/24 9PM
Test #1 FC 20.5, CC 1.5
Test #2 FC 22.0, CC 1.5
pump on low + 3 swim jets on low all night, cover open
5/25 5AM; washed all sample & test equipment with alcohol
Test #1 FC 20, CC 2.0
Test #2, FC 19.5, CC 1.5
Questions/request for comments:
1. What to make of the back to back 1.5 FC difference on 5/24?
2. What to make of the high CC's this AM. Can anyone confirm all the spring airborne stuff does not result in high CC's? Or rain contribute to CC's?
3. Depending on which tests I pick, the FC could pass or fail the OCLT.
4. Next steps?
Be sure you know how to take EVERY test to it's ENDPOINT. Are you doing that?1. What to make of the back to back 1.5 FC difference on 5/24?
Those results are quite normal, CC's are an indicator that the chlorine is actively working on contaminates. That test might give you .5 ppm tomorrowWhat to make of the high CC's this AM. Can anyone confirm all the spring airborne stuff does not result in high CC's? Or rain contribute to CC's?
If you mean add drops until no more color change, then subtract last drop, then yes I'm doing that. If you mean something else, please explain.Be sure you know how to take EVERY test to it's ENDPOINT. Are you doing that?
My FC tests last night were 3 drops off, and CC this afternoon 2 drops off. Seems like a long ways from 1 drop accuracy when the criteria for pass/fail are 1 dropThe tests have a tolerance of 1 drop and your results are pretty close to that tolerance. You keep going on the SLAM cause of the high CC. Junk getting blown into the pool could make some CC, but not stuff in the air.
My FC tests last night were 3 drops off, and CC this afternoon 2 drops off. Seems like a long ways from 1 drop accuracy when the criteria for pass/fail are 1 drop.
yep...well, whatever came with the test kit.Are you using the speedstir?