Jandy Aquapure Salt Production 00% - NEW Jandy chlorinator

EliaZinn

Active member
Mar 19, 2024
27
Miami FL
Hey all -

Here is my issue. I just installed a new Jandy Chlorinator (PLC1400) to replace my old one that was not working anymore and pins inside were corroded. Installed the system exactly as the old one was installed. When the system is on auto (Jandy Aquilink controlled) the chlorine output is zero (even though set to 70%). When in service mode, I am able to manually raise the level to 70% and it stays (even though screen flips between 70% and "Jo". (see attached photos of both)

- My Salinity level is quite high at 3.8glp although I dont think this would be the issue.
- Its a brand new Chlorinator so I dont think its a hardware issue.

What could be the issue? Did I leave out any useful info? Would a photo of the wiring or equipment help?
 

Attachments

  • IMG_0388.JPG
    IMG_0388.JPG
    275 KB · Views: 15
  • IMG_0389.JPG
    IMG_0389.JPG
    246.3 KB · Views: 15
  • IMG_0391.JPG
    IMG_0391.JPG
    196.2 KB · Views: 13
If by power cycle you mean turn off at the breakers (for some time) and back on - yes, I did. Is there a certain order that I need to adhere to?

Thanks
What breakers are you talking about?
 
What does the LCD mean?

• ‘LO’ – indicates that the water temperature is less than 51 deg. F

• ‘BO’ – indicates the boost cycle which can be activated by pressing the ‘Pool Temperature’ key for 10 seconds; it can be cancelled by holding the same key for 10 seconds.

• ‘EC’ - indicates the unit is being controlled by an external controller or ORP device.

• ‘JA’ – Indicates operation is controlled by a Jandy AquaLink RS or PDA, and system is in AUTO MODE.

• ‘JO’ – Indicates operation is controlled by a Jandy AquaLink RS or PDA, and system is in SERVICE or TIME MODE.

• ‘JB’ – Indicates operation is controlled by a Jandy AquaLink RS or PDA, and system is in BOOST MODE.
 
‘JA’ – Indicates operation is controlled by a Jandy AquaLink RS or PDA, and system is in AUTO MODE.

It should show "JA" if the Aqualink RS is in control.

Is the 4 wire communication wire connected?

Can you show the wiring?

Does your controller show a water temperature?

If not, replace the water temperature sensor.

1711914616082.png



 

Enjoying this content?

Support TFP with a donation.

Give Support
‘JA’ – Indicates operation is controlled by a Jandy AquaLink RS or PDA, and system is in AUTO MODE.

It should show "JA" if the Aqualink RS is in control.

Is the 4 wire communication wire connected?

Can you show the wiring?

Does your controller show a water temperature?

If not, replace the water temperature sensor.

View attachment 561648



When not in Service Mode - ie. auto - the display shows 00% as in the photo. If I try to change the setting on the panel, I get a "Jo" indicator as the Aqualink controls the settings (set to 70% in Aquilink).
When in Service Mode I am able to manually set the chlorinator to 70% and the display shows 70% production (alternates between 70% production and "Jo")
The wiring appears as in your diagram - although the "Aux 3 Relay) Has a line going to the transformer to the right of the "Chlorine Generator Power Interface Board" in the photo below.

I can take better photos tomorrow morning and send, just happened to have these in my phone.
 

Attachments

  • 325FAED6-3968-45E5-BE17-A6F8FE1870FE_1_105_c.jpeg
    325FAED6-3968-45E5-BE17-A6F8FE1870FE_1_105_c.jpeg
    251.9 KB · Views: 5
  • 2CA413CB-399A-44EF-B4E5-A1185C5E6FB3_1_201_a.jpeg
    2CA413CB-399A-44EF-B4E5-A1185C5E6FB3_1_201_a.jpeg
    359.8 KB · Views: 4
  • CE3031C1-D192-4B61-A012-545CE4F3F2FC_1_201_a.jpeg
    CE3031C1-D192-4B61-A012-545CE4F3F2FC_1_201_a.jpeg
    274.8 KB · Views: 5
  • 3169FDDC-10D4-4E4C-B60E-7BAEB9FC1651_1_201_a.jpeg
    3169FDDC-10D4-4E4C-B60E-7BAEB9FC1651_1_201_a.jpeg
    400.5 KB · Views: 3
  • 38F4507E-D12F-4F9D-BE23-B36F20B76A1D_1_102_a.jpeg
    38F4507E-D12F-4F9D-BE23-B36F20B76A1D_1_102_a.jpeg
    197.4 KB · Views: 5
What controller do you have for the Aqualink RS?

1711913106487-png.561638
 
When not in Service Mode - ie. auto - the display shows 00% as in the photo. If I try to change the setting on the panel, I get a "Jo" indicator as the Aqualink controls the settings (set to 70% in Aquilink).
When in Service Mode I am able to manually set the chlorinator to 70% and the display shows 70% production (alternates between 70% production and "Jo")
The wiring appears as in your diagram - although the "Aux 3 Relay) Has a line going to the transformer to the right of the "Chlorine Generator Power Interface Board" in the photo below.

I can take better photos tomorrow morning and send, just happened to have these in my phone.
CORRECTION -

When on auto and I try to manually change I get "JA" indicator - NOT "Jo" as said above.
 