T cell issue help

Blusangel03

Member
Oct 13, 2023
5
MS
Pool Size
29000
Surface
Vinyl
Chlorine
Salt Water Generator
SWG Type
Hayward Aqua Rite (T-15)
Hello! I just replaced my T Cell 15 on my Hayward aquarite and I do not have an option to see if the Tcell is set to 15. My board only gives me an 88-1 option where the Tcell option should be. Anyone know how to fix this? Thanks!IMG_0113.jpeg
 
Last edited:
Here’s another post describing a similar situation
Calling ☎️ @JamesW
 
You have a non-Hayward board.

Open up the box and show us pics of the board in it.
 
  • Like
Reactions: Mdragger88
Is the J4 jumper on or off?

1697285000612.png

45762222-d172-4fd0-aa7e-ffb9f7330f0e-jpeg.139204
 

Enjoying this content?

Support TFP with a donation.

Give Support
Can you show the board?

Can you post all of the diagnostic readings?

How are you testing the salinity?
Readings are as follows
5800
72
31.6
7.98
5p
-6100
88.3
R8.80

Salt tested at pool store
 

Attachments

  • IMG_0116.jpeg
    IMG_0116.jpeg
    534.8 KB · Views: 2
  • IMG_0115.jpeg
    IMG_0115.jpeg
    420.7 KB · Views: 2
Thread Status