- Aug 31, 2018
- 41
- Pool Size
- 20000
- Surface
- Plaster
- Chlorine
- Salt Water Generator
- SWG Type
- Jandy Aquapure 1400
So, been getting code 120/121 on my Aqua Pure system PLC1400, which is low current in forwards and reverse. Ran through the testing procedure and got 97 mVfor the current test, and 35V at the cell. System was installed in 2018
Looking at the flow chart, this say to replace the cell. Does this seem right? I would have thought low voltage would mean it isn’t working. #notanelectrician
Also, I did the test procedure to test the sensor and all tests failed.
Salinity reading was H.H. Should be 2.7-3.1
Low temp was 87. Should be 73-77
High temp was 95. Should be 89-93
Does this mean bad sensor or bad PIB? I have the new two probe sensor, and it’s in the correct program (A).