Dear Salt Chlorine Generator forum -
I have 3 year old Hayward T-15 cell that I have been using trouble free at least for 3 years. A few weeks ago I learned that I need to acid wash it on annual basis which I have not done so
. There were no build up that I could see on the cells.
So bought a cleaning stand, this morning followed the instruction, put the cable side on the top, poured 4:1 water to muriatic acid solution and left it for 10-15 minutes.
After reinstalling the cell, the salt reading only showed 2000 instead of 3200-3400 where it was before. The low reading automatically turned the generator off after a few minutes. Recalibrating the salt reading only shows the salt as high as 2200; then after a while will go back to 2000 again.
The voltage - 24.8 (also normal as usual)
Amperage 6.25 (also looks normal as usual)
Cell size somehow showed T-3 instead of T-15
- Is this a sign of a bad cell?
- Since the voltage and amperage still shows that it can still generate chlorine, is there a way to by pass the auto shutdown from false salt reading?
- Could this be coincidence that it happened after I acid washed the cell?
- How long is the warranty on the cell, the serial number starts with 3E16353-XXXXX
Thank you in advanced for the help!!
I have 3 year old Hayward T-15 cell that I have been using trouble free at least for 3 years. A few weeks ago I learned that I need to acid wash it on annual basis which I have not done so
So bought a cleaning stand, this morning followed the instruction, put the cable side on the top, poured 4:1 water to muriatic acid solution and left it for 10-15 minutes.
After reinstalling the cell, the salt reading only showed 2000 instead of 3200-3400 where it was before. The low reading automatically turned the generator off after a few minutes. Recalibrating the salt reading only shows the salt as high as 2200; then after a while will go back to 2000 again.
The voltage - 24.8 (also normal as usual)
Amperage 6.25 (also looks normal as usual)
Cell size somehow showed T-3 instead of T-15
- Is this a sign of a bad cell?
- Since the voltage and amperage still shows that it can still generate chlorine, is there a way to by pass the auto shutdown from false salt reading?
- Could this be coincidence that it happened after I acid washed the cell?
- How long is the warranty on the cell, the serial number starts with 3E16353-XXXXX