So once again we added 24 oz of MA mixed it in with the pool brush and checked it 2 hours later and still the same ph reading which is around 8.2. I really do not understand how 24 oz MA in a 5000 gallon pool does nothing at all. Makes no sense to me. On Saturday when we are home all day we plan to add 16 oz and test every 2 hours then keep adding every 2 hours if the test does not show the desired ph. If that doesn't work I don't know what to do.
If the pH test reagents are good this could be a weakness of the pH test. When you have pH over 8.2 the test doesn't change color very much so your pH could be well above 8.2 and the pH is changing and you just can't detect it yet.. A friend of mine had this problem when he accidentally dumped a bunch of caustic soda into the pool. pH went through the roof. Digital pH testers are available under $20 and they will measure much higher. He didn't have one so we took out 2 gal of pool water in a bucket and added small amounts of acid, stirred, then tested pH. Didn't take much acid at all for a 2 gal sample but we ratioed up to calculate the amount of acid required. Then we added 25% of the calculated amount so we didn't overshoot. It only took about 3/4 of the calculated amount. As Matt mentioned above pH should be adjusted a small amount at a time due to the accuracy range of the calculations. Anyway we got the pool in great shape over 12 hours. pH seemed to go up quickly for a while but it got to normal operation in a couple of weeks. I should caution that doing this method requires handling MA many times and at close range. We both have a LOT of experience working in chemistry labs so we handled it very carefully. It's very easy to splash a drop in your eye so safety glasses with side shields are a must and set this up on a bench so comfortable to work on so you won't trip while working. If' you're not comfortable with this get a digital pH meter.
This does beg the question why not use a digital meter all the time? Answer is they're a pain. You have to calculate them often and the electrodes on cheap ones don't last too long.
Sorry for the long post and I hope it's helpful.
Chris
Last edited: