EDIT-SOLVED: Confirmed that one of the new conductors got nicked during the pull, inside the damp/metal conduit was causing the intermittent trip. The lamp works fine now.
edit: I swapped in a GFCI only breaker, problem persisted. So I disconnected the Pentair lamp entirely at the JBox and...
OK...it has been the project from heck! After 22 years, the pool lights started tripping the GFCI. I read that you should first check/replace the GFCI since it is a quick/cheap/easy fix to start with. Well, that was not the problem. So I ordered new LED bulbs (converting from old halogen), new...
Hi. My spa light went out and I attempted to replace the T4 100W 120V halogen bulb. Not hard to do , except that the ceramic (?) base that the T4's prongs insert into has completed disintegrated. Any thoughts on what my options are? Has anyone ever done a in-enclosure repair? I am hesitant to. A...
My Hawyard Colorlogic have failed multiple times- only once under warranty- flicker of death, and we are finally replacing with Jandy. The transformer that is already in place is a Hayward. Can I use that or is there something unusual about it and I need a Jandy or other brand?
The housing for my pool light leaks and is not repairable. It's an old style that just clips in on the top instead of with a bolt. I can't find a direct replacement. Does anyone know where to find one or have an idea what I can replace it with?
Curious what others have seen with regards to longevity on the Hayward ColorLogic lights. I have a Hayward LPCUS11100, and my pool was completed in October of 2019 - so it's only a little over 3 years old... and just outside of warranty.
The other day we turned it on, it ran for about 5...