Search results

  1. hseeng

    Jandy TruClear with Jandy Pump setup

    I completed installing this unit. For anyone setting up a Jandy VS pump and a true clear this setup works perfectly. When you stop the pump from the JEPR controller (e.g to backwash) the Trueclear SWG automatically goes into stand by mode. On a 77,000l pool running it at 20-30% is enough...
  2. hseeng

    Jandy TruClear with Jandy Pump setup

    Thought I'd share a pump diagram to help others. In the next few weeks I will setup the unit as follows. Will be installing a Jandy TruClear with a Jandy VS FLOPRO 1.65 pump. I would like the units interconnected with TruClear using RS485 to the JEP-R pump controller. Advantage is when the...
  3. 1680882109700.png

    1680882109700.png

  4. 1680882028296.png

    1680882028296.png

  5. 1680881985651.png

    1680881985651.png

  6. 1680881340329.png

    1680881340329.png

  7. 1680881169728.png

    1680881169728.png

  8. 1680881161477.png

    1680881161477.png

  9. 1680881142066.png

    1680881142066.png

  10. 1680881078354.png

    1680881078354.png

  11. 1680880978244.png

    1680880978244.png

  12. 1680880864354.png

    1680880864354.png

  13. hseeng

    Pool salt recommendations

    In Canada... we have 2 major companies (Windsor or Sifto). Windsor Ontario has one of the largest salt mines underground in the world. Pool owners have suggested over the years we can use water softener salt that has no additives.... After a bit of research I found this out. Windsor® Clean...
  14. hseeng

    Need feedback - Jandy TruClear - Plumbing design

    Thanks for the feed back. Updated my pool in 2020 that was 30 years old. new heater, pump, filter, piping, liner. I had a SWG for 12 years. Was worn out so tried to maintain the pool using liquid and triclor pucks for 2 years. I liked the ease of use with a SWG Be interesting in the real...
  15. hseeng

    Need feedback - Jandy TruClear - Plumbing design

    Hi folks, I would like the forums feedback on my thoughts. I like to add back a SWG to my pool system. I have limited options (space) to add in a SWG cell after the heater and return lines. See pad layout below. As you can see by below diagram it believe the Jandy TruClear cell will fit...
  16. Jandy truClear.jpg

    Jandy truClear.jpg

  17. triopurelarge.jpg

    triopurelarge.jpg

  18. Screenshot_20200201-202352_Photos.jpg

    Screenshot_20200201-202352_Photos.jpg

  19. hseeng

    New liner - Water good for 6 weeks - Went cloudy over weekend

    Hi all, Please advise Should I "SLAM" the pool with Liquid or use none CL oxidizer (Potassium monopersulphate) which I bought? I dont want to bleach a new $5000 liner. I called the Lathan liners and asked how high can the CL go to below bleaching. They wouldn't answer the question. New...
  20. hseeng

    Still having Trouble keeping FC in pool

    Well very good news. Came back from Vacation and Pool is still crystal clear. We even had a huge rain storm and very high winds the day I got back 8 days later and the pool is still keeping CL levels very stable all this week. Just tested the water FC = 2 (the last 4 days) CC = < .3 Cannot...
  21. hseeng

    Still having Trouble keeping FC in pool

    Well this is what I'm going to do and did Added anther 900ml of CYA to skimmer today. I expect it would give me a reading of 55 total if tested Numbers @ 8PM FC 0.1 (if that) TC 0.5 PH 7 - 7.2 (really odd color to judge even with 7 drops) TA 110 Went swimming today in it. Nice and clear...
  22. hseeng

    Still having Trouble keeping FC in pool

    The Triopure is putting out clorine. I read 1ppm off the jets. I did a muratic cleaning of the plates even though its only been running on the SWG for 8 weeks. Triopure docs says I only need .5 to 1 ppm FC because of the ozone system. Starting to think I got hosed on this system for $1700 10...
  23. hseeng

    Still having Trouble keeping FC in pool

    HELP going on vacation! I’ve read quite a bit but still some odd things are happening. Details Test Kit - Taylor K1004 DPD (not FAS) Location Toronto, Canada, Water temp 70-80 SWG – Triopure 25 (with Ozone as part of unit) Pool timer - Running 12 hours a day or more. (Triopure runs...