  1. D

    Pentair UltraTemp connected to Intellicenter

    Update: I reverted my intellicenter software to a previous firmware, now it automates correctly.. On another note just prior to the update I notice the Pentair Home App and the Intellicenter was not showing the proper cooling set points, only showing the heating, although the Ultratemp was...
  2. D

    Pentair UltraTemp connected to Intellicenter

    I did reboot, the heat function is working correctly( heating and turning on and off through app) the cooling function is working to turn on the unit but will not turn it off. The below pics are 10 minutes after I increased temp in app. I would assume HP should be off by now.
  3. D

    Pentair UltraTemp connected to Intellicenter

    Not sure if it heats or cools, haven’t ran it long enough yet. I did just try the heat function, it turned on when and off through app like it should .
  4. D

    Pentair UltraTemp connected to Intellicenter

    Interesting enough, when a Pentair tech came out for my last unit, they stated that dint know how I was operating the HP remotely with this connection method and it needed an additional relay? Which contradicts the manual and Pentair HP tech support I spoke with.
  5. D

    Pentair UltraTemp connected to Intellicenter

    I did not, even changed address back to 1 and updated IC. With the manual not mentioning IC automation, is it correct to assume the proper way of connection is just using the COM ports and the yellow/green wire? Manual references the spade connection ?
  6. D

    Pentair UltraTemp connected to Intellicenter

    from Pentair, was issue with my other HP, I swapped out. Installed by PB originally
  7. D

    Pentair UltraTemp connected to Intellicenter

    See photos. Compressor seems to be running. If I switch the ultra temp to manual, it immediately stops when I increase temp.
  8. D

    Pentair UltraTemp connected to Intellicenter

    New replacement
  9. D

    Pentair UltraTemp connected to Intellicenter

    Seems as the compressor does shut off, but the fan continues to run(overnight) never stops.
  10. D

    Pentair UltraTemp connected to Intellicenter

    I reset the controller. Now the ultra temp will turn on when I drop the temp below current temp. If I turn it above it, how long should it take to turn back off?
  11. D

    Pentair UltraTemp connected to Intellicenter

    It was not working on 1 so a changed to 2 to see if I could get working
  12. D

    Pentair UltraTemp connected to Intellicenter

    Yes I have all 3
  13. D

    Pentair UltraTemp connected to Intellicenter

    I connected to the J5. Error gone. But unit will not stop running.
  14. D

    Pentair UltraTemp connected to Intellicenter

    Ok I will try, that, manual referenced ability to use J8.
  15. D

    Pentair UltraTemp connected to Intellicenter

    No, not when connected to J8 on Intellicenter (I get the “Serial COMM LOST” message on ULTRATEMP), when I connect to the JP3 port circled in the below photo, I do get the heart beat, but it doesn’t seem to respond as I had the cool temp set to 89 and the pool was at 86 and unit was running?
  16. D

    Pentair UltraTemp connected to Intellicenter

    It’s set up at Ultra temp. I see the readings in the intellicenter and the Pentair home app, the ultra temp will not respond to the temp adjustments See the photos of connections to my Ultratemp and my Intellicenter, the connections are circles in red. Both intellicenter and ultra temp are set...
  17. D

    Pentair UltraTemp connected to Intellicenter

    Having issue getting ultra temp to control with Pentair home app. I have Com wire connected to Ultra temp and to intellienter with the ultra temp set to Rs485 mode. Any help appreciated.
  18. D

    Below freezing temps . Should I run Ultra Temp

    Temps dropped last few days to low of 8 degrees and only high of 30 degrees next 5 days. Water temp in pool is now 30 degrees. Pumps on 3400 RPM 24/7,. Question is should I run my ultra temp in hope to keep water above freezing? I am currently bypassing it. Any other recommendations to prevent...
  19. D

    Leak in Pool

    It seems like one thing after another.
  20. IMG_0066.jpeg

    IMG_0066.jpeg

  21. IMG_0070.jpeg

    IMG_0070.jpeg

  22. IMG_0071.jpeg

    IMG_0071.jpeg

  23. D

    Leak in Pool

    I have pool drained now and PB is examining . On another note, Just curious if anyone thinks these spots are an issue or area of concern. They look like rust spots,
  24. IMG_0062.jpeg

    IMG_0062.jpeg

  25. IMG_0065.jpeg

    IMG_0065.jpeg

  26. IMG_0063.jpeg

    IMG_0063.jpeg

  27. IMG_0064.jpeg

    IMG_0064.jpeg