    AquaLink RS Not supplying power to pool Lights Junction Box

    I had a similar issue a couple years back, mine ended up being a faulty relay controlling my light feature in the Aqualink control box... in my case there's actually what I'll call side A and B on the relay, with side A the one that was in use and faulty... Side B was unused, I tested it with my...
  2. J

    My turn to replace a single speed pump...

    Update - I did some experimenting with speeds over the weekend...at 2000 RPM I still get no flow errors, but I did notice my 2 farthest returns from the pump were not circulating any water... I have 6 total returns, plus a beach bubbler and a return into my spa for the waterfall into the pool...
  3. J

    My turn to replace a single speed pump...

    Thanks Pete, I will be doing that in the coming next couple of weeks... given I have a holiday weekend coming up with guest, I wanted to get my chlorine levels back up since it sat idle for 6 days... I certainly will tinker with the speeds to see what works best for my set up though! thanks...James
  4. J

    My turn to replace a single speed pump...

    Update...Pump is installed, had to do a few plumbing and base setting mods due to differences in the union connectors and different offsets between the old Hayward and new Waterway pumps... I have set steps 1&2 to cover my 7 hours of normal daily operation, with step 1 at highest speed and step...
  5. J

    My turn to replace a single speed pump...

    Pump is arriving today, hope to have it installed before sundown... after a lot of reading, my initial thought for setup is to something similar to what user dhy4b did with his, basically setting up the step 1&2 programs for daytime, and the step 3 program to be used with my spa in spa mode at...
  6. J

    My turn to replace a single speed pump...

    thanks Hootz...unfortunately, my wet portion has several worn out parts too, so I am replacing the whole assembly... going with the Waterway PD270, it has the V-green 2.7HP motor... it should arrive mid-week, I'll repost after I get it installed... thanks everyone for the input!
  7. J

    My turn to replace a single speed pump...

    Thanks... mine is currently plumbed horizontally...
  8. J

    My turn to replace a single speed pump...

    Thanks Pete, I'll give it a look.... thanks for reference thread, a lot of good info there I can relate to with my Jandy control center and spa situation as well...is there a minimum RPM to use on the variable speed pumps relative to the salt cell? I was concerned about flow errors if the RPM is...
  9. J

    My turn to replace a single speed pump...

    Hi all, it s been a while since I've posted, my pool/heater/spa, have been rocking along nicely for a couple years now...until yesterday... my ~10 year old main pool/spa pump appears to have given up the ghost...it is a single speed , Hayward Ecoflo 2.7THP...which means now I get to convert to...
  10. J

    Jandy Pool Heater problems

    Hey Coach... I haven't been on in a while, just now reading your post... My "pool" side is now doing the same as the "spa" side did, with my max temperature now only 97 when it shuts off... I looked at my control board, replacing the potentiometers isnt something I would tackle myself, they are...
  11. J

    Jandy air temp sensor showing much warmer than reality after snowmageddon...

    thanks all.. it definitely was the radiant impact off of the snow, once it melted over the weekend, all back to normal... case closed!
  12. J

    Jandy air temp sensor showing much warmer than reality after snowmageddon...

    Found it, it is directly underneath my control box and in the shade... there is also significant snow on the ground underneath that was in the sun.. I am thinking some reflective heat may have been radiating upwards off the snow from the sun, causing the sensor to read warmer than normal... I...
  13. J

    Jandy air temp sensor showing much warmer than reality after snowmageddon...

    All my equipment appears to be in the shade... but having said that, I'll ask the dumb question... where is my outside air temp sensor? only sensor I know of is the one strapped to my PVC pipe for the water temp...I have an older Jandy RSLink system, there's no display inside the control box...
  14. J

    Jandy air temp sensor showing much warmer than reality after snowmageddon...

    The sun is finally shining here in North Texas but its still 27 degrees outside... I just happened to look out and see that my water feature had turned off, which didn't seem right... I went to my Jandy PDA and it shows its 42 degrees outside, which is why my water feature turned off (I have it...
  15. J

    Equipment pad enclosure/cover recommendations ?

    Very very nice!! Not sure what I will do yet, just looking for options and ideas, but most likely will be a DIY project...thanks for sharing!
  16. J

    Equipment pad enclosure/cover recommendations ?

    Thats awesome looking! Great job!
  17. J

    Equipment pad enclosure/cover recommendations ?

    Room is no issue, it is free standing with no other building or walls to contend with... I don't think I want any type of masonry wall, but more of either a picket or screen type enclosure... main purpose will be to keep the leaves out :-)... it is a good 30+ feet away from my pool/spa, so noise...
  18. J

    Equipment pad enclosure/cover recommendations ?

    Looking for any recommendations on pool equipment pad enclosures with top cover... I live in the country with beautiful oak trees, consequently I constantly battle leaf issues in and around my pool equipment... open to pre-fab or DIY thoughts... thanks...James
  19. J

    Jandy Pool Heater problems

    Update... I was able to verify my water temp showing on the Jandy RSLink PDA with a thermometer. It seemed to be accurate (52.7 on the thermometer, 53 on the PDA remote)... so I tried what member ntxpool (Mike) did back in 2012... The Jandy/Laars LT400 has a control panel with a temp dial for...
  20. J

    Jandy Pool Heater problems

    Ok... I did remove both my limit sensors, they both had a little bit of corrosion, but not bad... I cleaned both and reinstalled them, but did not make a difference in the symptoms I’m experiencing... was wondering I might have a bad temperature sensor? I did remove and reinstall it a couple...
  21. J

    Jandy Pool Heater problems

    Moved from here. Hello - I did not see any final resolution on this thread ... My 14 yr old LT400 just began this weekend having the same symptoms after working great for the past couple months... I set the temp to 104, it heats to 98 and shuts off... when it cools down past 96, it comes back on...
  22. J

    DIY Skimmer replacement for inground pool - yes or no?

    OK, did a couple things - I re-examined the shutoff valve on the non-functioning skimmer, there was some fine debris on the diverter that could have been keeping it from sealing all the way, so cleaned and re-assembled it. I also rotated the clear plastic piece of my pump lid by 90 degrees...
  23. J

    DIY Skimmer replacement for inground pool - yes or no?

    Thanks Mark, good to know... I think it has to be somewhere around the pump at this point.... I guess one thought is it could be sucking air around the shut off valve on the one bad skimmer line I mentioned earlier...I'll keep troubleshooting...thx!
  24. J

    DIY Skimmer replacement for inground pool - yes or no?

    Mark, Yes, I did that early on, tightened both plugs, and have run water over them with no change in the bubbles... I also removed the lid and re-examined the o-ring, the lid, the pump housing, etc but cannot see anything obvious on any of those surfaces. Also did the running water test on the...
  25. J

    DIY Skimmer replacement for inground pool - yes or no?

    Update - I am still seeing air bubbles in my pump when running, but dont believe its in any of the suction active suction feeds. I did replace the o-rings on the actuator valve that controls pool/spa mode function, it didnt make any difference. Shutting off the suction feeds do not make any...
  26. J

    DIY Skimmer replacement for inground pool - yes or no?

    Update - I have another skimmer back in operation, appears its only issue was the leaking shut off valve I repaired with new o-rings, all good on that one...I was able to do a pressure test on the remaining skimmer back to the shut off valve, and pinpointed a leak under the deck in the pipe... I...
  27. J

    DIY Skimmer replacement for inground pool - yes or no?

    Update- so far, I have found my pump lid seal was bad, it is replaced... all my shut-off valves for each skimmer and main drain had at least 1 o-ring that was broken on the diverter shaft, all have been replaced...the air is significantly reduced in now in my pump, but definitely still have...
  28. J

    DIY Skimmer replacement for inground pool - yes or no?

    I did notice some seepage around my pump lid, I took it off, cleaned and lubed it well, and am not noticing anything there now... but seems pretty certain I have something going on between the pump and 2 of my skimmers...was wondering if the shutoff valves themselves might be the source, but I...
  29. J

    DIY Skimmer replacement for inground pool - yes or no?

    Setup - 14 year old inground pool, approx 45K gals, gunite with plaster, spa waterfall into pool, 3 skimmers and main drain for suction, 2.5 HP Hayward Energy/RS pump, all valves/filter/lighting/heater are Jandy... all skimmers and main drain have separate shut off valves at equipment pad It...