Search results

  1. M

    Raypak 406A Burner won't fire but do get pilot

    Thanks - cleaned everything, still didn't work. Ordered a new pilot assembly, installed it and it fired right up... Now after a bit I get "High Limit 2 Fault" my thermostat's rubber gasket looks out of round...I did test the thermostat in hot water and it appears to work. Was thinking of...
  2. M

    Raypak 406A Burner won't fire but do get pilot

    Flame Strength is "0". Voltage is 26.2 I get the voltage to the PV post on the Gas Valve and the pilot does light...I do not get 24 v to the MV post which to me means that one of the safety switches is tripped or the main board. All switches seem to be fine. Questions: Is there a fan or...
  3. M

    Raypak 406A Burner won't fire but do get pilot

    Thank you for the reply. I also tried that, buffed all the pieces...with no luck. Questions: Is there a fan or blower in the 406A? If yes, does it need to be blowing in order for the burner to fire? Next steps: I did order a new pilot assembly which I will try when it arrives...
  4. M

    Raypak 406A Burner won't fire but do get pilot

    Burner won't fire... Corrective action taken: All safety switches operate, I disconnected them and jumpered the wires getting an error when open and no error when jumped roll over switch works, error when open, no error when jumped or connected. Spark at pilot and it lights fuse on main board...