Search results

  1. K

    Easy Touch 4 not working

    Jim, New transformer in and system is working. Thanks again for all the help!
  2. IMG_2137.jpg

    IMG_2137.jpg

  3. K

    Easy Touch 4 not working

    Like I noted. I'll let you know when the new one arrives. Appreciate all the help.
  4. K

    Easy Touch 4 not working

    Jerry, thanks for the reply. See my updates above. But I did want to answer your mystery question. Attached is a better pic. This EMI filter is connected to the transformer for the Intelleclor control panel.
  5. IMG_2116.jpg

    IMG_2116.jpg

  6. K

    Easy Touch 4 not working

    Reconnected the transformer. Verified power coming into the transformer where black power lead connects. Re-verified that still no voltage coming out of the pin connector. Tested each pair of colored wires, alternated leads from multimeter from same colored wires to make sure I wasn't missing...
  7. IMG_2126.jpg

    IMG_2126.jpg

  8. K

    Easy Touch 4 not working

    Understand and did check for voltage for each of the wires as shown in pics. This was done while the power was on. Got no reading of power from the transformer.
  9. IMG_2122.jpg

    IMG_2122.jpg

  10. K

    New member

    Thanks! Lived here all my life! 7 months out of the years it's great, 5 months are like the meme!
  11. 1595343767345.png

    1595343767345.png

  12. K

    Easy Touch 4 not working

    Jim, Pulled the transformer so I could get to it. Will hook it back up to test it. Where do I test for power coming in. I know the 120v is coming from the breaker. Do I have to pull the tape off the transformer? Also, conductivity is good on all three circuit breakers connected to the...
  13. IMG_2125.jpg

    IMG_2125.jpg

  14. K

    Easy Touch 4 not working

    Jim, I get no reading while checking between the two pins on the connector. REd/red, orange/orange and blue/blue. I get 240 on aux2.
  15. IMG_2123.jpg

    IMG_2123.jpg

  16. IMG_2124.jpg

    IMG_2124.jpg

  17. IMG_2122.jpg

    IMG_2122.jpg

  18. K

    Easy Touch 4 not working

    Thanks and yes so I could check for voltage coming out of the transformer. Can't get any reading out of the connector.
  19. K

    Easy Touch 4 not working

    Jim, Should have included this pic to start with. You are correct on the 240V to each pump. The gound fault has been working, I had checked this as my sprinkler system timer is plugged into it. It is on a sperate feed than the controls.
  20. IMG_2120.jpg

    IMG_2120.jpg

  21. K

    Easy Touch 4 not working

    I saw your post from last year about the transformer and that's why I asked you about this situation. See the attached pics. The control board transformer is wired in the 115V configuration like on the left of the schematic pic. Both sides of the panel buss read 120V. So yes on the pumps. The...
  22. IMG_2119.jpg

    IMG_2119.jpg

  23. IMG_2117.jpg

    IMG_2117.jpg

  24. IMG_2118.jpg

    IMG_2118.jpg

  25. IMG_2105.jpg

    IMG_2105.jpg

  26. K

    Easy Touch 4 not working

    Jim, Thanks for the response. Nothing lights up. None of the buttons on the panel work. My IC40 lights do not come on either. I have a remote that works but it does not connect. Unit is wired for 120v and have 120v out of all breakers. I cant get a reading on my voltmeter from the...
  27. K

    Easy Touch 4 not working

    Post moved from old thread -- here. Jim, Just joined the forum. I have an Easytouch 4. local utilty changed out my meter. Had all my electronics off except for my pool. Now my ET4 screen is blank. Have been trouble shooting. All breakers are good, have power to the transformer(520653) as...