Search results

  1. jklocke

    ! DIY'r trying to hook up Pentair Intelliconnect to pump, IC40, & heat pump heater!?

    Welcome to TFP! Like Allen mentioned, you need RS-485 connections from the pump AND from your IC40 power center to the Intelliconnect. Both the pump and the power center should be powered directly from the breaker, not through the Intelliconnect. You only use RS-485 to control them. Are...
  2. jklocke

    Fiber Stars Fiber Optic Cable

    Thanks, but unfortunately the only thing left is the cable and the outlet where it used to be plugged in. I guess I need to spend the time and dig up the cable and see what shape it's in. I thinks it's really strange that no one has made a LED replacement for the FiberStar system.
  3. jklocke

    Fiber Stars Fiber Optic Cable

    I've been looking for an alternative off and on the last few years with no luck. The previous owners of my pool got rid of the light wheel but left the UltraGlow cable in the channel in the pool. A couple of times I thought I had found an LED cab;e option that would work, but never pulled...
  4. jklocke

    How to install a Pentair IC40

    While Pentair recommends installing the IC 40 vertically, they also recommend that your SWG should be installed after the filter and heater. Your best place for installation is where the old RJ+ is installed. As mentioned before, the IC 40 does not have to be installed vertically, and your...
  5. jklocke

    Questions about wiring IntelliConnect with non-pentair SWG & Heater

    Thanks for coming back and giving a final update on this thread. Glad everything is working!
  6. jklocke

    Beta-Testers for IntelliConnect Firmware

    If you send me a PM, I can give you the name and email of the person I was in contact with last fall and early this spring. I will tell you that I never received a response from him to the last email I sent in April after I opened my pool for 2024. Maybe Ron @MyAZPool has more info from his...
  7. jklocke

    Questions about wiring IntelliConnect with non-pentair SWG & Heater

    That’s how I have my pump scheduled and I’ve never checked to see if it shuts off or not. I don’t care. Attached it my schedule. I only run the highest speed when I quickly need to lower the water level a little bit, which is rarely. 1200rpm is 22gpm for me, so it skims well even at that low...
  8. jklocke

    Questions about wiring IntelliConnect with non-pentair SWG & Heater

    Well that's not ideal! Does the app show the pump is on when it's actually off? How did you start it back up? With the app or on the pump? The bigger question to me is why does the pump shut off after it primes. Is it scheduled to run 24/7 at a low speed? When I power on my pump, it...
  9. jklocke

    Intelliconnect connections

    Also, the RS-485 connector in the Intelliconnect only uses the green and yellow wires in the RS-485 cable.
  10. jklocke

    Questions about wiring IntelliConnect with non-pentair SWG & Heater

    Glad things are working now! How's the SWG working through the relay? Does everything seem good with that?
  11. jklocke

    Questions about wiring IntelliConnect with non-pentair SWG & Heater

    I'd start by reseating your RS-485 wires from the pump to the Intelliconnect just to make sure everything is ok there. The RS-485 block in the Intelliconnect pulls off to make it easier to screw down the connections (in case you haven't already figured that out). You've got the newer...
  12. jklocke

    Questions about wiring IntelliConnect with non-pentair SWG & Heater

    Your wiring diagram looks good to me, and your plan sounds good. Same old disclaimer - I’m not an electrician, etc etc etc. 😁 Glad I was able to give you some ideas to help get you ready for your install this weekend. Be sure to let us know how it goes!
  13. jklocke

    Questions about wiring IntelliConnect with non-pentair SWG & Heater

    Your diagram looks correct to me. I’m not positive, but I think the heater should be wired directly and not through the Intelliconnect. I’m not an electrician, but I know there should not be multiple wires under the contacts on the breaker. A pigtail with wire nut connections or junction box...
  14. jklocke

    Questions about wiring IntelliConnect with non-pentair SWG & Heater

    The AC Power connection on the left side of the high voltage area only provides power to the Intelliconnect. From there I have seen it wired 2 ways - 1) using jumpers from those 2 connections to the Line connections on the relay, or 2) having a line come directly from a circuit breaker to the...
  15. jklocke

    Questions about wiring IntelliConnect with non-pentair SWG & Heater

    Travis - Yes, you should change the 240v breaker for the pump to GFCI. Check out this link for more info on breakers. You are correct the pump connects to the Intelliconnect via RS-485. The Intelliconnect can be powered by either 120v or 240v and connects directly to the breaker. Your SWG...
  16. jklocke

    Intellivalve connect to Intelliconnect

    Welcome to TFP. Does the Intellivalve use 120v or 24v? I'm pretty sure it's 24v The relay on the Intelliconnect can only output 120 or 240 depending on how it's powered. I think you could make it work by using a transformer. Hopefully someone who knows way more about the electric on the...
  17. jklocke

    Intelliconnect with Superflo VS

    Welcome to TFP. This thread has good instructions for getting the Intelliconnect and Superflo VST working together - WhisperFlo VS and intelliconnect First step is to make sure that the Pentair Home app is talking to the Intelliconnect. Once that is working, power everything off and then...
  18. jklocke

    Will superflo vs connect to intelliconnect

    It is my understanding that the pump itself has to be manufactured after 10/15/2020 for it to be able to talk to an Intelliconnect controller. The firmware in older Intelliconnect systems is what often needs to be upgraded for it to talk to newer pumps.
  19. jklocke

    Pentair Intelliconnect Relay CircuPool SWG Question

    I think running the pump 24/7 as slowly as you can is a better idea to make sure there is always flow to the SWG. I can't find any threads here where anyone has ever tried to do 2 flow switches for 1 SWG. Keep things simple and you'll be ok.
  20. jklocke

    Pentair Intelliconnect Relay CircuPool SWG Question

    What would an additional flow switch do? One is enough to ensure that the SWG won't come on if no water flows through it. A better way to protect your system would be to wire the pump and SWG onto the same timer, with the pump on the Line side and the SWG on the Load side. That way the pump...
  21. jklocke

    Pentair Intelliconnect Relay CircuPool SWG Question

    Which model pump do you have? Make sure that your pump is compatible with the Intelliconnect before you buy one. You need to be able to control the pump through the Intelliconnect for the relay protection to work. Using an Intermatic pool timer or a wifi timer to turn the SWG on and off would...
  22. jklocke

    Pentair Intelliconnect Relay CircuPool SWG Question

    Glen - On the Pentair Home app for the Intelliconnect, there is an option in the relay settings to require the filtration pump to run when the relay is active. That should take care of the situation you're asking about. If the Intelliconnect will work with your pump , I think a better option...
  23. jklocke

    How to disconnect from Pentair Intelliconnect remote/monitoring system temporarily

    Your firmware and software info is under product overview in the Intelliconnect settings on the app. I was told by Pentair this week that this is the current firmware. Sometimes it can take a little bit to get help from Pentair but once you do they are very helpful.
  24. jklocke

    How to disconnect from Pentair Intelliconnect remote/monitoring system temporarily

    In the past I've disconnected the RS-485 hub in the Intelliconnect to give control back to my IC40 and pump. Be sure to turn off power to all devices before doing that. I would contact Pentair support and see if there are any firmware updates for your Intelliconnect. That solved my...
  25. jklocke

    Pentair IntelliConnect & IntelliChlor IC 40

    Can you change the output on the IC40? The cell light is only on when the IC40 is producing chlorine. I would double-check the RS-485 connections at both ends. Be sure to have the power off on both the Intelliconnect and the IC Power Center when you are working on that. If that doesn't work...
  26. jklocke

    Pentair IntelliConnect & IntelliChlor IC 40

    You should see the % output change on the IC40 after you change it in the Pentair Home app. There is a slight delay, but never more than a few seconds for me. If the IC40 is connected correctly through the RS-485 cable to your Intelliconnect, you should only be able to change the output in the...
  27. jklocke

    Pentair Pool Automation

    IntelliConnects with host firmware 1.6.2.5 and above now have the ability to control the SuperFlo VST manufactured after 2020, and I’ve seen a couple of members here doing just that. I have an Intelliconnect and it works fine for my simple pool. But if the Intellicenter Lite had been available...
  28. jklocke

    Will the Intelliconnect work with the Superflo VS?

    Which model Superflo VS pump do you have? The newer ones with RS-485 port will now work, even though the manual says they do not. I think it's model 342002. If your pump is too old, having an Intellisync and an Intelliconnect seems like a disaster waiting to happen. Better to buy a new pump...
  29. jklocke

    Pool light control question

    I don't have a color light, but here is what the options are for adding a light to one of the Intelliconnect relays: All Pentair color lights fall under that one category, so it seems likely your light would work.
  30. IMG_0545.jpeg

    IMG_0545.jpeg