Search results

  1. D

    Above Ground Pool Pump tripping GFCI breaker

    You may also want to get a new GFCI receptacle. As a home inspector, I know that GFCI receptacles are prone to failure and nuisance trips. You may just have a receptacle going bad. If you change receptacle and it is still tripping then you will need to look at the pump, ground and bond.
  2. D

    Help Fixing Pool Light: Cord or Light?

    I would also recommend power to the pool lights and equipment that is not low voltage be GFCI protected.
  3. D

    Hayward Pro Logic Salt level

    Cell temp is 74, water temp is 77.
  4. D

    Hayward Pro Logic Salt level

    Jamesw, thanks for the info. Do you recommend staying with the Hayward brand or are any of the 'generics' decent.
  5. D

    Hayward Pro Logic Salt level

    I think the system was installed in 2011. 3E1005-2131444 is the serial number.
  6. D

    Hayward Pro Logic Salt level

    OK, it is a Hayward Pro Logic system. It is reading my salt at 2500 - 2600 but when I take a sample to my local pool supply house it reads at 3100. I have recently cleaned the cell with a 1:4 muriatic acid solution and it appears clean. I have done the instant read several times, switching...
  7. D

    Hayward Pro Logic Salt level

    Moved from here. I am having the same problem. The only difference is my system is a Hayward Pro Logic with a T-15 cell. The the salt reading be manually re-set on this controller?
  8. D

    New here

    Hi, I'm David and am fairly new to pool ownership. I bought a house at the end of 2015 and got a pool with it. It has a Hayward salt system. So far, been pretty easy to get the hang of.