Search results

  1. D

    Can you help ID this cover?

    When I looked previously I only saw a bunch of safety info- "keep cover in place at all times", etc.... BUT in relooking at it in bright sunlight, there is very faint printing on the underside. Aquastar 10CC100. Mystery solved!!! Problem is that it's disco'd due to the newer standards since...
  2. D

    Can you help ID this cover?

    You are correct- this is for the equalization port below the skimmer but main drains look to be the same.
  3. D

    Can you help ID this cover?

    Hi folks! To this point my Googling skills have eluded me and I've not been able to locate this replacement part. It's the clear cover that is used on my pebble top equalization drains (and maybe main drains?). Some other designs appear to be two piece as is this one, but not sure if those are...
  4. 1664916484597.png

    1664916484597.png

  5. 1664916513751.png

    1664916513751.png

  6. D

    Jandy Lite 2 LJ Heater Not Working [SOLVED]

    My 13yr old Lite 2 LJ400 heater was working fine, until it wasn't... After chasing several things, it ended up being a bad temp sensor. A few general troubleshooting tips that might help others... Make sure your heater's controller/LCD display is working so you can see any error codes. In my...
  7. 1618517918117.png

    1618517918117.png

  8. D

    Jandy JVA 2444 only turning one way [SOLVED]

    I didn't see any other threads on this topic so I figured I'd share my experience on solving a JVA (model 2444) issue on my Jandy iAqualink system. Situation... I have a combo pool/spa with the spillover feature, along with Jandy iAqualink automation. Every so often, the spillover would dribble...
  9. 1617840615003.png

    1617840615003.png

  10. D

    Jandy Lite2 Heater Issue

    UPDATE: I figured I'd go ahead and see what I could get on the pins of the power converter and that is putting 115V on at least one pin, which may lead to that not being the fail point. Could there be anything else that would stop voltage from getting to the ignitor when the Aqualink controller...
  11. D

    Jandy Lite2 Heater Issue

    My Jandy Lite2 LJ400 Heater went out in the last couple days. Looking to the experts here for some guidance on next steps for troubleshooting. I have taken a multimeter to various test points and can report the following... All fuses passed (3 in total) The ignitor measures ~235ohms, which is...
  12. D

    iAqualink app not working 11/25

    @PoolGate thank you for the reply. I had previously tried logging out, deleting the app, resetting my password, all to no avail. The issue was in trying to reset it to the same password due to other integrations that would have broken. That did not work - apparently the fix is to change your...
  13. D

    iAqualink app not working 11/25

    Anyone seeing a resurgence of this issue? Drove me crazy last week with the AWS outage and now it seems to be back. All systems showing online, inc. web access, however nothing I do gets the APP to work on any iOS device. Fluidra's phone support is abysmal currently - tried multiple...
  14. D

    Jandy ePumps: VSSHP220AUT or 'new' VSSHP220DV2A

    I have searched all over and even called Jandy who wasn't much help... I was all set to replace my dead single speed pump with a Jandy ePump model# VSSHP220AUT (no control needed since I have iAqualink). Then I saw there is a 'new' ePump model VSSHP220DV2A. Does this DV2A model provide anything...
  15. D

    Single speed pump to variable speed?

    Thanks for the help! Reprogrammed things this evening and tested with DIP #3 change for spillover. Ready to roll! New ePump going in this weekend. Can’t wait!
  16. D

    Single speed pump to variable speed?

    One more question... in comparing the published dimensions of the Stealth SHPF vs. ePump, the union locations look to be identical, which would imply a drop in replacement (with new cable/programming for ePump in Aqualink). Do you know if wet side is the same on both models - and if so, would it...
  17. D

    Single speed pump to variable speed?

    Super helpful resource! I’ll do some studying on spillover. Sounds like this swap/upgrade is more homework and programming than I expected. Wish it was winter and not pushing 80 degrees here in SC...
  18. D

    Single speed pump to variable speed?

    Thank you for the prompt reply! I do have Jandy automation - I upgraded to iAqualink after the PDA died. I understand what you’re saying, but currently pool mode always operates the waterfall. Maybe there’s a way via Jandy programming to switch spa valves (which control waterfall) off per your...
  19. D

    Single speed pump to variable speed?

    I have a single speed 2HP pump that feeds a pool/spa combo (with waterfall from spa to pool). I kept the pump motor on life support two years ago with a capacitor replacement but now it is all but dead. I can’t find much info on the impact of a VSP on the waterfall. Currently the waterfall...
  20. D

    Any clue what this pipe is / where it goes?

    We purchased a home with a pool a couple years ago and I've been following TFP guidelines with great results (first time pool owner when we moved in). It looks like there was some work done after original install (before we bought it) to perhaps remove something or add something in the...
  21. 1591117895086.png

    1591117895086.png

  22. D

    Jandy PLC1400 - Replace Cell Only?

    I started following the TFP method about 6 months ago and am loving it. Thank you all for the awesome resources and eduction on this site! My question is on advice if I should replace just the Jandy 1400 salt cell itself, or bite the bullet and replace the whole kit (inc sensor, cabling etc)...