  1. O

    Inexpensive Mobiletouch2 Replacement Battery

    If anybody has a Mobiletouch2 remote with a dead battery... instead of buying the ridiculously priced Pentair replacement, I used this < $30 replacement, manufactured by Cameron Sino (I got mine from Walmart, but it's widely available)...
  2. O

    Intellicenter i5PS personality board photo needed

    has anybody got a good resolution photo of the back side of an i5PS personality board? I found this one from @pjt , but I want the other side...
  3. O

    Easytouch V1 to V2 brain transplant

    Ever since I read Jerryt's firmware update post back in 2015 I've wanted to swap the micro-controller chip on a "V1" Easytouch with one that will make a "V2" Easytouch... I finally did it tonight and it works! Figured I'd document the process in case anybody else felt like tinkering...
  4. O

    Jandy RS8 System Transformer pinout

    Anybody know what the Jandy system transformer's 3-position connector pinout is? I think it's a 24vac transformer and I'm guessing maybe there's a center tap, but I don't know which pin is which. It's the orange connector in the top left of this picture (thanks to @ilyzislin)...
  5. O

    Blown Intellitouch iLink

    Not sure if anybody is still using these things but I had the opportunity to repair one after it was damaged in a Florida storm (see? I keep saying all the stuff blows up in Florida and Texas). Figured I'd do a quick write-up in case anybody else needs to fix one. The iLink units connect to...
  6. O

    Easytouch 520946z Transceiver card compatibility issues

    This is more of an informational post rather than a question... but I don't believe that all versions of the newer Laird chipset transceiver cards (part 520946z) are compatible with all Easytouch firmware versions. TLDR - I could not set the wireless address using 3 different 2.030 firmware...
  7. O

    Issue updating Intellitouch Firmware from 1.051 to 1.190

    Hey folks, I just updated the firmware on an Intellitouch system for a fellow TFP member @riverlvr ... his system had an Indoor Unit at T1.051 (Service/Trainer version), and an outdoor unit at 1.130. I updated both to 1.190. The problem is that he had 1 VS pump set up - but after updating the...
  8. O

    Pentair MobileTouch 1 Battery Replacement

    I've talked to a few folks that have Pentair MobileTouch 1 (1st gen) controllers with dead batteries. I've got some broken units so figured I'd pull out a couple of battery packs and get the make/model etc. so people could hopefully get cheaper replacements. The double sided tape holding the...
  9. O

    Setting Link ID on Screenlogic Wireless Link (Quest version)... [SOLVED]

    Hi folks, I've been tinkering with Screenlogic Wireless link cards to try and figure out how to reset the Link ID. The Link ID is the 8-digit number printed on a yellow sticker on both units - and the IDs must match for the two. At the moment, if one board fails you have to buy a whole new...
  10. O

    Lightning vs Intellitouch

    I've been fixing an intellitouch mainboard that was involved in a lightning strike and I thought it was interesting enough to share... I've only ever seen lightning damage the comm ports - but on this board it blew out rectifier BR2 (for the 12vac input), inductor L1 (between that rectifier's...
  11. O

    Has anybody still got the Pentair Firmware file with Easytouch ver 2.150?

    Does anybody still happen to have the installer zip file that contains the 2.150 Easytouch firmware? The file name is in the format "installer_mmddyy.zip" I do know that 2.160 is the latest release and I have the files for 2.160 and 2.140 (installer_101014.zip and installer_022017.zip...
  12. O

    Pentair transformer/3amp breaker confusion

    Hi guys, I've got an older (8 years or so) intellitouch system with the old style faceplate/bezel that has the low voltage breakers for electronics/relays/valves all in a row, like this: The newer styles seem to have them in a 2x2 grid, like this picture: The low voltage breakers are...
  13. O

    Anybody got the 1.160 firmware files for the intellitouch controller?

    I know the current firmware version on the pentair pools site is 1.170, but I'd really like to get the 1.160 version. The pentair site doesn't have archived versions. When you download, unzip, and run the installer exe you get a pemicro folder... inside the pemicro/pkg12z/s19 folder are all...