Search results

  1. Hayward Pool

    Calculations and need to replace pump, line.

    Using gauges to determine the TDH on a system only needs two readings. One off the discharge of the pump (pressure gauge) and one off the suction of the pump (vacuum gauge). In looking at your specs I believe you have one reading to many. The pressure gauge at the discharge port will...
  2. Hayward Pool

    hey HAYWARD - move your legs

    The springs are not sold separately. The pods come with the springs. Looks like the pods, wings, flaps and shoes may need to be replaced also. The wings, shoes and flaps are wear parts.
  3. Hayward Pool

    Cloudy water

    I have the manual but not a link, the filter does not have regular laterals. I need to have an email to upload.
  4. Hayward Pool

    Vac is sucking on drains

    Not sure how old the cleaner is but if the cleaner is a year old make sure the feet, wings and shoes are in good shape. If the cleaner goes onto the drain and crawls off within a minute or so that is normal. If this is a problem from the beginning make sure the main drain suction is turned...
  5. Hayward Pool

    Hayward above ground pool skimmer part

    Can you tell me the model of the skimmer.
  6. Hayward Pool

    Anyone replace Hayward Blower Vacuum Switch?

    The part number for the blower vacuum switch is IDXL2BVS1930. The first thing to check is the hose to the blower to make sure it does not have any cuts or has come loose. The blower vac switch just closes and completes a circuit. wires can go either side. Could also be a board problem...
  7. Hayward Pool

    vac hose stuck in skimmer-help!

    Sometimes just raising the pool level up higher on the tile line can solve the problem. Also make sure your returns are not pushing the hose in that direction. Redirect the returns.
  8. Hayward Pool

    New pool owner -No Flow light

    If the flow light is staying solid the most likely problem is the flow switch not closing. Could be a bad flow switch or inadequate flow.
  9. Hayward Pool

    Heater Problems

    Based on the information provided I would check the gas train first. Could be as easy as removing and cleaning all the orifices. Spiders like to get in there and block the gas flow to the ignitor. When you have an IF code that normally means insufficient fuel. Could be blocked gas line...
  10. Hayward Pool

    Hayward Pool Heater FAIL (with pic)--new Heat Exchanger Available?

    When going up in BTU's make sure the gas line will support the larger heater. I have dealt with many customers who went up and had problems. Going up only 50,000 BTU's should not be a problem but be cautious
  11. Hayward Pool

    Pondering the big swap to VS / dual speed

    Bobo was right, FL has one of he lowest costs for electricity. A surge protector would be a priority if I was in your shoes.
  12. Hayward Pool

    Hayward Ecostar 3400 Making loud Squeel

    Not sure what this sound is but I am going to try and find out. - - - Updated - - - OK, most in the field feel it is the fan in the back rubbing or out of alignment. Take the back shroud off and check. I also sent you a private message.
  13. Hayward Pool

    Filter/pump recommendations

    The filter combo is fine for your application.
  14. Hayward Pool

    Hayward 400 IO Failure code

    Since the flame sensor is rusted and the connection is not good there may be a poor ground. Replace the flame sensor and if it does not solve the problem check all the wiring for the ignitor. If the wiring is ok, replace the ignitor at that point. As always we strongly recommend that this...
  15. Hayward Pool

    Pool Pump Replacement Question

    As the previous person stated the Super Pump is a medium head pump that is not suited to run a floor cleaning system. I see from the pictures you have a valve for the system. You will need a high head pump if running the floor cleaning system is a must. Not sure what floor cleaning system...
  16. Hayward Pool

    Help with pool volume

    Well to a great forum of helpful people.
  17. Hayward Pool

    Hello from Fayetteville, Ga

    Hello from California, glad you found the site.
  18. Hayward Pool

    Hayward DE filter pressure drop

    If you have a valve in front of the pump and can take it apart, there might be leaves stuck in the diverter.
  19. Hayward Pool

    Help with new set up

    I have provided a picture of where the two wires from the controller go for hook up. Strongly recommend that this be installed by a technician who is familiar with the control and heat pump.
  20. Control hook up.jpg

    Control hook up.jpg

  21. Hayward Pool

    AGP Heater - Hayward HP50HA questions

    Yes on the ground next to the filter is fine.
  22. Hayward Pool

    Hayward Ecostar 3400SVP pump Drive Error

    Good day, the error you are having tells us the drive is most likely bad. You stated 4 years old. I will private message you with contact info. Hayward might be able to help.
  23. Hayward Pool

    Pool Lights Hayward Color Logic

    OK, looks like the color module may not be to end of year. To many other projects on the hook.
  24. Hayward Pool

    Pool Lights Hayward Color Logic

    Good Day ymmoti, you are right. The Omni has better functions installed than the ProLogic but not what the ColorModule does for the ProLogic. I have asked for an update and will post when available.
  25. Hayward Pool

    Backwash valve leaking....OK to install ball valve on discharge line ?

    Hayward's backwash valve have a different size for the top and bottom o-rings The top one is the largest one with part number SPX0410Z2. The bottom one is smaller with part number SPX0410Z1.
  26. Hayward Pool

    Pump LED Light On Control Board

    Good Day, the light is an LED with a long life. It will always be on.
  27. Hayward Pool

    Swapping cord with burnt connector on Hayward T-Cell

    The cord or connector is not replaceable.
  28. Hayward Pool

    AGP Heater - Hayward HP50HA questions

    Just spoke to the Heat Pump guys at Hayward. The manual is being changed as this Heat Pump does not have a pressure switch, it has a flow switch. My bad.