Search results

  1. Jimrahbe

    Pentair Easytouch PL4/PSL4 Wireless Setup

    J, You are missing the Protocol adapter... This 'adapter' changes the 4 wire RS-485 signals into Ethernet signals that can be connected to your home network. Do you have the Protocol adapter?? I notice your system is in the Service mode.. It would normally be in the Auto mode.. Nothing...
  2. Jimrahbe

    Trying to Get Rid of the Pool Cleaning Blues with Robotic Cleaner

    Thomas, The 614iQ can be controlled by an app.. You can schedule it to run when you want.. You can manually 'drive' it around, and it will climb the wall so it is easier to take out of the pool.. I can live without all of this things... :mrgreen: I almost never use the app, so for me...
  3. Jimrahbe

    Trying to Get Rid of the Pool Cleaning Blues with Robotic Cleaner

    Thomas, See this review... New EVO 614i Robot Pool Cleaner Review Thanks, Jim R.
  4. Jimrahbe

    Mechanic with a pool

    Thomas, If you have the skills to work on cars, then you certainly have the ability to learn how to maintain a pool.. We would be glad to get you pointed in the right direction... Thanks, Jim R.
  5. Jimrahbe

    I don’t feel water coming up from main drain skimmer hole

    909, Even when a main drain is working perfectly, you can't even feel any water flow right at the drain area.. It will not help keep the deep end clean at all. They might have a slight effect on the filtration, but not enough that anyone could see it, or measure it.. Until recently I had two...
  6. Jimrahbe

    Hi, new guy from tx

    j, Ok, then I won't say it... :poke: Jim R.
  7. Jimrahbe

    I don’t feel water coming up from main drain skimmer hole

    909, Not how it works.. To pull water from the skimmer, the pump creates a suction.. This suction has no way to get to the main drain pipe.... Unless there is a floating diverter below the skimmer basket.. I have had zero luck with getting floating diverters to work for more than a few...
  8. Jimrahbe

    Pentair Intellicenter App - how to avoid Heater from running all night

    B, It is called an egg-timer.. If you manually turn something on, it will shut off after X amount of time. X can be set to whatever you want.. Each circuit has an egg-timer.. The default is 12 hours. Settings, Advanced Settings, Circuits, Spa, Egg-timer.. Thanks, Jim R.
  9. Jimrahbe

    Uh Oh. No Thermal Regulator found upon inspection

    R, Yep... That happens pretty often.. Jim R.
  10. Jimrahbe

    Taylor K-2006 (new) vs Leslie’s???

    R, Let me put it this way... I'd rather let it drip down my leg, as to walk into a Leslie's just to use their bathroom, much less have them test my pool water... :mrgreen: If you take the same water to 4 different pool stores, you will get 4 different answers.. :( Trust the kit you...
  11. Jimrahbe

    I started getting this on the iAquaLink app when trying to set the speed to anything less than 3450 on my pump.

    Jon, Turn the heater off and 'feel' the water flow going back to the pool... Does it feel normal or slow?? You could have a very dirty filter causing weak flow, or one of the internal parts inside the heater may have broken off and is clogging the flow. I guess my point is... Try to...
  12. Jimrahbe

    Brand new pool owner, struggling to figure out my equipment

    PS, My 'guess' is that is where your broken SS pump is getting its water. In this pics you can see the pipes going to the bubblers.. There are 4 pipes, so either you have 4 bubblers, or one pipe goes to something else. You can see the PVC ball valves, mostly set to off.. I assume they are...
  13. PS Valve pic3.jpeg

    PS Valve pic3.jpeg

  14. Jimrahbe

    New EVO 614i Robot Pool Cleaner Review

    Mark, We should have a contest.. I bet I can get my robot out of the pool, before you can get you phone out of your pocket, and get the app turned on... :mrgreen: It is a nice touch, just not something I ever use. Glad you like it.. Jim R.
  15. Jimrahbe

    Brand new pool owner, struggling to figure out my equipment

    PS, I had the waterfall and pool returns backwards.. I used common sense, which the guy who plumbed your system, apparently does not have... :mrgreen: You really should never shut off your pool returns.. I have no clue what the B valve does, and we won't know until you get the pump on the...
  16. Jimrahbe

    Brand new pool owner, struggling to figure out my equipment

    PS, I want you to run some tests... using this pic.. 1. Set valve 'A' so that the handle points 180 degrees from where it is in the above pic.. (Handle points to the right) a. I suspect that this will shut off your waterfall and send all the water back to your pool returns...
  17. 1744930230654.png

    1744930230654.png

  18. Jimrahbe

    Replacing Jandy VS for ?

    div, As Allen points out above... your pool builder is an idiot... A 3 HP single speed pump would be too large for your pool.. But a 3 HP VS pump is perfect.. The whole idea of having a VS pump is to run it as slow as you can, and still get the job done.. The larger the pump, the slower it...
  19. Jimrahbe

    Intermatic T101P timer - possible 240 volts application?

    Ah!! I now understand your screenname... :mrgreen: :poke: Thanks, Jim R.
  20. Jimrahbe

    Brand new pool owner, struggling to figure out my equipment

    PS, Please tell me about your pool... I assume you just have a pool, and no spa.. Correct? How many skimmers? I assume one, Correct? Do you know where your Single speed pump gets its water?? I assume from your main drain, but you may have another input in the pool??? How many drain...
  21. Jimrahbe

    Brand new pool owner, struggling to figure out my equipment

    PS, Yes, much better... :goodjob: I'll look at them after lunch.. Thanks, Jim R.
  22. Jimrahbe

    Brand new pool owner, struggling to figure out my equipment

    PS, I'm trying to map out your equipment pad and need more pics as you have a weird set up.. Please show me pics from both sides so I can see where all the pipes go.. A couple from the top would also help. Thanks, Jim R.
  23. Jimrahbe

    Brand new pool owner, struggling to figure out my equipment

    PS, Pentair makes it next to impossible for any new person to understand their automation logic... :mrgreen: Please tell me what you would like to happen and 'maybe' I can translate their manual for you.... :) I too am not a SunTouch user, but it should be similar with the EasyTouch...
  24. Jimrahbe

    Easytouch 8 Spillway feature

    Harold, If the waterfall pump is being controlled by the RS-485 com port, and you have a speed set for "Spillway" then I would expect the waterfall pump to run... anytime you are in the Spillway mode.. You can't have two different functions with the same Circuit Name.. Maybe I just don't...
  25. Jimrahbe

    How do I get this under control?

    r, If you travel a lot, then a Saltwater Chlorine Generator (SWCG) is the answer you are looking for... You can go away for a week or two, and your pool will not even know you were gone... :mrgreen: Saltwater pools are the easiest type of pools to maintain. You also need to quit putting...
  26. Jimrahbe

    No lights on IC -40 on startup

    Shades, Tell us more.. Do you have an external Power Center, or is the power Center built-in to an EasyTouch or IntelliCenter??? Basically, there is a SWCG transformer that converts your High Voltage AC into about 24 Volts AC.. This then goes to the Surge card which changes the 24 Volts AC...
  27. Jimrahbe

    IC-40 into Easy Touch

    Roger, Great job!!! :goodjob: From your posts, I had assumed that you could do it, but I did not want to push you into doing something you were not comfortable with.. Almost everything is difficult the first time you do it, and then you look back and say "Well, that was easy"... Glad...
  28. Jimrahbe

    Flow problem?

    Jen, It may not be the filter, but logic says you need to eliminate the most obvious device first and see what happens. Have you been vacuuming up leaves?? if so, another thing to look at would be a clogged impeller. @JamesW Good catch.. I did not even notice that display... :goodjob...
  29. Jimrahbe

    EasyTouch Programming VST with Heater

    Ed, Your pump's speed is controlled by whatever 'circuit" or circuits are on... My guess is you have a speed assigned for Pool Circuit... On the same page, you just select heater.. When the heater asks for heat, the pump will speed up to whatever speed you assign. Do you have ScreenLogic...
  30. Jimrahbe

    IC-40 into Easy Touch