Hi,
I am troubleshooting my Aquapure SWG system and had the following question.
My Aquapure system has firmware 08020A07, so on the salinity/flow sensor module I need to select PgmB as shown below.

On the Power Interface Board, there are two LEDs labeled as "A" and "B"(in below picture), one of the LED will lit during operation and it will alternates between A and B.

My question are
I am troubleshooting my Aquapure SWG system and had the following question.
My Aquapure system has firmware 08020A07, so on the salinity/flow sensor module I need to select PgmB as shown below.

On the Power Interface Board, there are two LEDs labeled as "A" and "B"(in below picture), one of the LED will lit during operation and it will alternates between A and B.

My question are
- Are the LED "A" and LED "B" associated with the PgmA and PgmB selection on the salinity/flow sensor?
- My salt cell seems only producing chlorine when LED "B" is lit. what could be the reason? the salt cell and DC cable are relatively new.