I have no idea. What should I be looking for, the valves controlling the water flow? I have intellivalves, so I don't touch them. I will go check to make sure they are operating as they should. However, the heater errors out whether I'm using the pool or spa.Seems like an actual overheat situation.
Are the valves set correctly?
That seems low unless the thermistor was hot.
Try replacing the temp sensor to rule out a faulty sensor.
If the temp still climbs fast, then is is maybe a flow issue or maybe scaling or sooting.
Show the valves.What should I be looking for, the valves controlling the water flow?
Show the valves.
You can measure the exhaust temperature using an infrared thermometer…
the app shows 30GPM & 1,979 RPM in pool mode.The valves look ok.
What is the pump speed?
Does the pump show a GPM?
Minimum flow is 40 GPM.
Is the filter clean?
Try the new sensor and see what the temp is.