TheHomeGuru

In The Industry
Apr 9, 2020
10
Georgia
IMG_1007.jpg
I had to replace the cell but whoever first installed it had the union joints flush against the pad so it is impossible to tighten or loosen by hand. Also, the fittings leak unless you over torque them with channel locks. The installer must have had the same issue because he used thread compound. The new cell came with unions so I plan to redo this mess and replace five elbows with only two and mount the cell vertically above a check valve in line above the pump outlet. Then loop back with two elbows to the return. I'll have to dig out to add a coupling at ground level.
This is coming from the Dejoyaux filter which has a two speed pump and a bypass loop.
My other question is, what's the point of this Heyward pump since the system included the two speed? The problem is when the main pump is on high speed, the Hayward has to be running as well or else the pressure blows out the strainer pot gasket.
 
Show us your entire equipment pad.

Where do the pipes that go into the ground connect to?
 
That's it. Everything else is contained in the Desjoyaux poolside box.
So someone spliced in another pump and SWCG into the dejoyaux box? :oops:

The extra pump may have been added because the smaller pump may not have been able to flow enough with the extra head pressure.
 
Yes. The pentair cell functions without a control box and could go in the dry box with the main pump but this cell is controlled by the Easytouch controller which is mounted about 50' away.
If the cell could have been installed in the dry box, is it a dumb question to ask why not just run wire from the easytouch controller into the dry box instead?
 
  • Like
Reactions: TheHomeGuru
So someone spliced in another pump and SWCG into the dejoyaux box? :oops:

The extra pump may have been added because the smaller pump may not have been able to flow enough with the extra head pressure.
Maybe. But I wouldn't call it a smaller pump and the lines are on the same level.
If the cell could have been installed in the dry box, is it a dumb question to ask why not just run wire from the easytouch controller into the dry box instead?
True. I just found a 50' cable on Amazon.