First season for new pool and learning & tuning as we move along....
I am noticing our IC60 occasionally isn't happy with flow and puts the infamous red light....
I'm trying to determine what the optimal flow range is to not cut it too close but not have to run VSF full bore all day.... also have a heater in the mix with a bypass and trying to figure out tuning the intellivalve to close more of the heater flow off so most water is going through circ but giving some flow through heater plumbing while off....
VSF is running at 2500 rpm and flow meter after ic60 is stating around 25 GPM.... Pentair Quad DE 100 is reporting pressure around 20 psi.
1. Keep reducing flow to heater while it is off via intellivalve to see if I can increase GPM going through IC60
2. Consider doing first filter clean to see if the filter needs cleaning to improve GPM
3. Just run VSF over 2500 rpm to make the IC60 happy from 6a-4p daily
other ideas thoughts?
I am noticing our IC60 occasionally isn't happy with flow and puts the infamous red light....
I'm trying to determine what the optimal flow range is to not cut it too close but not have to run VSF full bore all day.... also have a heater in the mix with a bypass and trying to figure out tuning the intellivalve to close more of the heater flow off so most water is going through circ but giving some flow through heater plumbing while off....
VSF is running at 2500 rpm and flow meter after ic60 is stating around 25 GPM.... Pentair Quad DE 100 is reporting pressure around 20 psi.
1. Keep reducing flow to heater while it is off via intellivalve to see if I can increase GPM going through IC60
2. Consider doing first filter clean to see if the filter needs cleaning to improve GPM
3. Just run VSF over 2500 rpm to make the IC60 happy from 6a-4p daily
other ideas thoughts?