Hello. I am building my own pool, and am working on figuring out the plumbing. I would love some expert input on my design.
Here are a few design features:
- I have 2 channel drains in my pool: the main circulation drain and a water feature drain.
- I have floor returns in the pool to use when heating the pool. Planning ahead for a future heat pump.
- I have a floor return in the spa to use when in pool mode to create the overflow. I think this is typical, but not sure.
- I have 3 bubblers with the outer two tied together, and the center home run. This is so if we have 2 chairs in the middle of the sun shelf, I can run the outer 2 bubblers, or if not, run all 3.
- I have 2 water bowls that are tied together.
- I have a 24" waterfall (sheer decent) in the pool.
- I have a 24" spillover from the spa into the pool.
- I have 2 pumps: one for pool circulation and spa mode, and another just for water features.
Here are a few questions:
- I've read that I need a water feature filter for at least the waterfall. So, should I just put a water feature filter on the waterfall, or just do another filter for all of the water features (as drawn)?
- Do I need a check valve on the spa floor return only? I assume this is necessary when in pool mode so that the water doesn't try to equalize with the pool through the pool returns.
- I am using Pentair IntelliCenter and IntelliChlor. I believe when in spa mode, it turns off the IntelliChlor so that you don't over chlorinate the spa. Or, should I take the jets off before the IntelliChlor, since I have a separate spa floor return for the spillover?

- Yellow circle: 2-Way Diverter Valve
- Orange circle: 3-Way Diverter Valve
- Green circle: Check Valve
- SWCG: Salt-Water Chlorine Generator (IntelliChlor)
- The valves that have an "A", indicate actuators for automation.

Thank you in advance!
Here are a few design features:
- I have 2 channel drains in my pool: the main circulation drain and a water feature drain.
- I have floor returns in the pool to use when heating the pool. Planning ahead for a future heat pump.
- I have a floor return in the spa to use when in pool mode to create the overflow. I think this is typical, but not sure.
- I have 3 bubblers with the outer two tied together, and the center home run. This is so if we have 2 chairs in the middle of the sun shelf, I can run the outer 2 bubblers, or if not, run all 3.
- I have 2 water bowls that are tied together.
- I have a 24" waterfall (sheer decent) in the pool.
- I have a 24" spillover from the spa into the pool.
- I have 2 pumps: one for pool circulation and spa mode, and another just for water features.
Here are a few questions:
- I've read that I need a water feature filter for at least the waterfall. So, should I just put a water feature filter on the waterfall, or just do another filter for all of the water features (as drawn)?
- Do I need a check valve on the spa floor return only? I assume this is necessary when in pool mode so that the water doesn't try to equalize with the pool through the pool returns.
- I am using Pentair IntelliCenter and IntelliChlor. I believe when in spa mode, it turns off the IntelliChlor so that you don't over chlorinate the spa. Or, should I take the jets off before the IntelliChlor, since I have a separate spa floor return for the spillover?

- Yellow circle: 2-Way Diverter Valve
- Orange circle: 3-Way Diverter Valve
- Green circle: Check Valve
- SWCG: Salt-Water Chlorine Generator (IntelliChlor)
- The valves that have an "A", indicate actuators for automation.

Thank you in advance!