Hey Everyone,
I’m new the forum (looks like a great community!) and am hoping to get some help with my pump problem. My pool pump all of the sudden stopped working correctly a few days ago. This pump was purchased in 2018 and has been working perfectly until now.
The pump is a 2 speed unit but I rarely run the slow speed. Regardless, when the pump is turned on
I get a low pitched humming/buzzing sound for about 6 seconds and then it stops/shuts off.
I’ve read quite a bit about various causes of humming on this forum but haven’t seen what my pool pump is doing in any prior threads. The unit will operate normally when I switch on low speed - sucks water into the pump and pushes it through the filter and jets in the pool. It has no abnormal sounds while running on low. The motor spins freely and the centrifugal switch operates as expected
Now when I look under the back cover when I switch it on high - the motor is actually spinning in the opposite direction! It makes that horrible humming sound and then shuts off after a few seconds. If I try to “kick start” the pump by running it on low and then quickly switching to high, the motor will stop spinning in the correct direction and reverse direction and turn off after a few seconds.
I’ve replaced both the start and run capacitor and the pump is still having the same operation.
Any help would be greatly appreciated! I’m slowly watching my pool turn green since the salt cell won’t turn on when it is on low flow setting



I’m new the forum (looks like a great community!) and am hoping to get some help with my pump problem. My pool pump all of the sudden stopped working correctly a few days ago. This pump was purchased in 2018 and has been working perfectly until now.
The pump is a 2 speed unit but I rarely run the slow speed. Regardless, when the pump is turned on
I get a low pitched humming/buzzing sound for about 6 seconds and then it stops/shuts off.
I’ve read quite a bit about various causes of humming on this forum but haven’t seen what my pool pump is doing in any prior threads. The unit will operate normally when I switch on low speed - sucks water into the pump and pushes it through the filter and jets in the pool. It has no abnormal sounds while running on low. The motor spins freely and the centrifugal switch operates as expected
Now when I look under the back cover when I switch it on high - the motor is actually spinning in the opposite direction! It makes that horrible humming sound and then shuts off after a few seconds. If I try to “kick start” the pump by running it on low and then quickly switching to high, the motor will stop spinning in the correct direction and reverse direction and turn off after a few seconds.
I’ve replaced both the start and run capacitor and the pump is still having the same operation.
Any help would be greatly appreciated! I’m slowly watching my pool turn green since the salt cell won’t turn on when it is on low flow setting