Recent content by Stevekell

  1. S

    Tristar prologic wiring different than ecostar?

    Jim... I want to thank you so much for all of your help.. it fired right up...your assistance is greatly appreciated...This is a great website and so cool to have nice knowledgable people on here.
  2. S

    Tristar prologic wiring different than ecostar?

    Thanks so much for your help...I got the connectors etc... and finishing up now...one last q... the instructions say I should have all DIP switches off... that sound right?
  3. S

    Tristar prologic wiring different than ecostar?

    Thank you Jim. The readout says Main Software revision- 4.40 and Display revision is 3.12. I am using the Hayward shielded cable provided with the pump which is 2 wires ( black/ yellow) and 1 bare wire to run to pump. Do I need to put that shielded cable in flex conduit or can I use the cable...
  4. S

    Tristar prologic wiring different than ecostar?

    Hi Jim... attached are two photos. I understand the wiring. I am running the two data wires from the Aqua Plus controller and connecting to the RS485 data plug at the pump. My question is what do I do with the four wires that are already in the RS485 data plug at the pump..? Do I disconnect...
  5. IMG_0400 pool pump wiring data.jpg

    IMG_0400 pool pump wiring data.jpg

  6. IMG_0402 pool pump wiring.jpg

    IMG_0402 pool pump wiring.jpg

  7. S

    Tristar prologic wiring different than ecostar?

    Jim... thank you so very much... for sharing your awesome knowledge on this site. I see now and have identified the correct wires on the control panel to run the new conduit. The RS 485 have four wires already attached to pump... . Do I leave the the (two) A and B wires that are already...
  8. S

    Hayward Pro-Logic Problem

    Hello.. I am replacing my Ecostar with Tristar 2.7 VSP... I have a question about the 2 DATA wires that were attached to COMBUS 7 and 8 on the ECOSTAR which run from the PROLOGIC panel. Where do they attach on the TRISTAR? Thanks for any help. Steve
  9. S

    Tristar prologic wiring different than ecostar?

    Thanks very much for the response... My setup with PROLOGIC.. I know that it is compatible with it... I have been hearing that similar Tristar models now have separate data line conduit needed instead of branching off the data lines from the single conduit... I guess I will find out shortly...s*...
  10. S

    Tristar prologic wiring different than ecostar?

    I am replacing my Ecostar with Tristar W3SP3206VSP. Is there any differences in the Prologic wiring of the two data lines? I selected this pump as it will line up with my piping etc. Thanks for any input or guidance.
  11. S

    Hayward Ecostar 2.7 VSP Pump problem-

    My Hayward Ecostar 2.7 ..8yers old...seems to be binding up... I tried to see if the impeller will move freely and I turned the rear Allen wrench nut and it is very difficult to turn..needed players to turn Allen wrench.. sounds gravelly when turning. Checked for blockage debris etc.-nothing...
  12. S

    Cyclone Blower Help

    Does anyone have winter pool blowout instructions for the CYCLONE blowing through the pump filter. I made an adapter pump lid( extra one on EBAY) from the info on this great informative website. Closing pool for first time... just received the Cyclone. Thanks.
  13. S

    Installing a Surge Protector

    I have a Hayward TriStar VS variable speed pump. I have a pool subpanel. Do you wire the Surge protector in to the same breaker that the Hayward TriStar VS variable speed pump is on or do you add a breaker. In my case on the breaker for the Hayward TriStar VS variable speed pump, I have a two...