Recent content by msickler

  1. M

    Hayward Heat Pro (HP21104T) - Busted PVC Elbow Sensor Holder

    Quick follow up, I did order the "Waterway Plastics Thermowell, 2" Sx2 Spg 90O W/Airbleed" from Amazon - Worked great. Thanks for the tip on the thermowell search
  2. M

    Hayward Heat Pro (HP21104T) - Busted PVC Elbow Sensor Holder

    Hey Team - Long shot here, but I messed up closing my pool last year, had covid brain and wasn't firing on all cylinders, and it seems my heater took a bad one. There's a 90 degree elbow at the bottom of the heat exchanger that holds the temp sensor, the internals of the elbow cracked and it...
  3. 2022-05-17_20-40-06.jpg

    2022-05-17_20-40-06.jpg

  4. 2022-05-17_20-39-40.jpg

    2022-05-17_20-39-40.jpg

  5. M

    Hayward Super Pump 2 speed wiring to Aquaplus SWG

    Wired it back to the switch, started up just fine. I didn't see anything standing out on the SWG side, but I'm leaving that alone till spring. Thanks for your help, I'll be back in the spring to figure this out!
  6. M

    Hayward Super Pump 2 speed wiring to Aquaplus SWG

    I opened the hood and everything looks correct, I'm worried when I initially hooked it up wrong I blew something... I'm outta time though, just finishing this build in mid October, In Wisconsin, so "Winter is Coming"... I'm going to hook it back up to the switch and see if it powers up. i...
  7. M

    Hayward Super Pump 2 speed wiring to Aquaplus SWG

    Yeah, i checked how the relays are wired, looks to match the diagram & the config for pump & Aux look right. This is how it was configured, when it would turn on and the pump would stop after seconds:
  8. aplus aux setting.jpg

    aplus aux setting.jpg

  9. Aplus Diagram.jpg

    Aplus Diagram.jpg

  10. aplus filter setting.jpg

    aplus filter setting.jpg

  11. M

    Hayward Super Pump 2 speed wiring to Aquaplus SWG

    well, I configured as discussed above, now the pump kicks on for a couple seconds, then shuts off. It's not tripping any breakers, sounds like a protection mechanism in the pump. If I leave it on it'll try again in a few seconds and turn off right away. Odd thing is even if I set the...
  12. New Pump Wiring v2.jpg

    New Pump Wiring v2.jpg

  13. M

    Hayward Super Pump 2 speed wiring to Aquaplus SWG

    Awesome, Thank you! I'll let you know the end result
  14. M

    Hayward Super Pump 2 speed wiring to Aquaplus SWG

    Ahh, that's a little different than I thought, does this correct then? Red - Low Speed Black - High Speed White - Common Green - Ground
  15. New Pump Wiring.jpg

    New Pump Wiring.jpg