Recent content by Mobile785

  1. M

    Re-calibrate Aqua-Rite

    Sorry for the extended delay in getting back to you. It was the Salt Cell, as soon as I replaced it the problem went away and the recal holds fine.
  2. M

    Keep having to Re-calibrate Salt Reading

    It's roughly 30,000 gallons. The pump usually runs daily in March 1 thru Oct 1 for 8 hours per day. During the winter months it only runs for 4 hours per day unless the freeze prevention kicks on. PH is usually a OK, last year we had a spike over the winter and then an algae bloom which...
  3. M

    Keep having to Re-calibrate Salt Reading

    I have an Aqua-Rite SWG, the replacement T-15 cell is aprox 4 years. The problem I'm having this year is the Salt reading is way off. It keeps dropping to 1900 to 2200 and stops generating. 2 different pool stores have told me 3200 and 3100. I've re-calibrated it several times and after...
  4. M

    Removable couplers?

    And now I know why I've never seen them before.... HAHAHA. Thanks for the info.
  5. M

    Removable couplers?

    Has anyone seen these black couplers before? It looks like it's designed to allow you to fully disconnect the valve without having to cut the PVC? I've never seen this before. Does anyone know where can I get them? Jimmy
  6. 1651929493181.png

    1651929493181.png

  7. M

    Multiport valve opens when running

    I have a Hayward DE 48sqft filter with a multiport valve. When running in filter mode all is fine. On anything else, backwash, waste, rinse etc.. there's no much pressure that it pushes the valve up on its own and water come out the backwash are pool returns. Also when I say it pushes it...
  8. M

    Cooling water thoughts, Good idea or wishful thinking

    See this is why I asked here :-) I would think that it wouldn't as it would be underground in a closed system where no air could get to it not to mention no sun to burn off the chlorine that's in it. But I could be wrong. If I am wrong and I most likely am, I guess I could always move the...
  9. M

    Cooling water thoughts, Good idea or wishful thinking

    We live in GA and our pool water tends to get into the low to mid 90's this time of year. I've been look all over this forum as well as other internet sites to find a way to cool the water. The best that everyone comes up with is to run the pump at night with a fountain. While that does work...
  10. M

    AquaRite SWG Problem

    I did look at the posts and there did appear to be some discoloration and was ready to buy a new one for it, but what stopped me was when the tech said it sounds like its a stuck relay. Is there a way to test the varistor? Jimmy
  11. M

    AquaRite SWG Problem

    I have an AquaRite SWG that has stopped generating. The only light on the system is the Power Light and the display reads "9900" I've reset the system by powering it off for several minutes and when I apply power again I get the same results Power light only. I usually got the power with No...