Recent content by Michelle W

  1. M

    IntelliChlor cholrinator does not have power

    Bought it last summer. I will check the date
  2. M

    IntelliChlor cholrinator does not have power

    Disconnected power, unplugged from the bottom of the automation box, reset the the breaker (it appeared to stay in).. connected the chlorinator back up and plugged in power... Breaker tripped as soon as the power hit it. Change the fuse?
  3. M

    IntelliChlor cholrinator does not have power

    Yes, It is labeled the IntelliChlor Breaker, I will try it.
  4. M

    IntelliChlor cholrinator does not have power

    My IntellicChlor Cell does not show power this morning. The is a circuit breaker in the main panel that is "tripped" and will not reset. Everything else is working. Cell was replaced 1 year ago and is clean. Had a lightning storm last night, wondering if it tripped it, but everything else has power.
  5. M

    Replaced Intellichlor IC40

    I replaced my Intellichlor IC40, it is controlled by Pentair Easy Touch system. Do I have to make any adjustments to the current settings on the Easy Touch? Do I leave at 100% or adjust? Just changed it today, so salt levels are adjusting. Pool is five years old, so Intellichlor had just quit...
  6. M

    Pentair IC40 Issues - ICHLOR 30

    Can you put chlorine tabs in pool while I wait on filter switch to be delivered?
  7. M

    Phosphates - 100 acre peanut field

    News. So based on last recommendations...I slowly lowered pH and have kept chlorine just below shock level...kept pump on and vac going daily. PROGRESS! Water is clear, bottom is blue, still vacuuming fallout...thanks to all for your help. Will let you know how it goes after next field spray.
  8. M

    Phosphates - 100 acre peanut field

    Test results tonight 7-20 Ph 8.2 FC 15 CC .5 TA 120 CH 210 CYA 40 Started shock last night.cleaned filter twice today. Particles falling out, vacuuming.running filter continually. Water looks healthier today. Still a work in progress. Copper is added in spray tank as a minor element...
  9. M

    Phosphates - 100 acre peanut field

    Thanks, this all makes since and I have some background with nitrates and their use...so I get it. I do have the complete Taylor kit and do my own testing. I started the shock process tonight with bleach, will report tomorrow. Thanks, I just needed to talk this thru with someone other than a...
  10. M

    Phosphates - 100 acre peanut field

    I know there is a surfactant and probably another chemical added to the tank mix, trying to get my son run down to get exact application he is using.I know something is put in to foam as a row marker.Sprayed yesterday, waiting to evaluate...Will post answers when I get them.
  11. M

    Phosphates - 100 acre peanut field

    It was ppb. 28,000 gal round, vinyl. TC 5 FC 8.5 CC .5 Ph 7.8 TA 110 CH 260 CYA 40 Spray was Bravo
  12. M

    Phosphates - 100 acre peanut field

    So, my pool is beautiful, I have been using the BBB method for a out 15\16 months...I live in the middle of a hundred acre peanut field that is now on a 7-10 day cycle of fungicide spraying. Last year, the pool turned a strange color green once and nothing regular helped so I finally had a...
  13. M

    Tropical Storm Debby and BBB

    13 inches of rain in 3 days, and my pool is great! Stayed clear the entire time just kept managing the water level and the chlorine. Today it is a dry day, checked all levels....only needed chlorine and small amount of muriatic acid!.....Love it! :-D
  14. M

    Florida AGP people, what is your winter/closing routine?

    I am in north Florida and choose not to close mine. It is just as easy to add extra chlorine, keep it clean, clear and ready to go. On really cold nights I will run the pump all night otherwise, just vac it a couple of times, still run filter. Pretty easy to keep clean, if leaves are a problem...
  15. M

    Converting from pristine blue to BBB

    Ok, so I feel good about the numbers, can see the bottom, but not clear have run 24/7 for 7 days. Just keep it running??????? FC 4 CC .5 TA 120 CH 290 CYA 40 CL 5 pH 7.5