Recent content by mbear2k

  1. M

    AutoPilot Pool Pilot Digital Nano - Cell Volts/Amps

    I think the issue is resolved. Get this - my replacement control board was at a factory default of 3 amps max. Ran for two seasons like this! Went to hidden 'Factory' menu which you enable at power up, and a new menu item "Factory" shows up in the menu list. - Remove power - Apply power -...
  2. M

    AutoPilot Pool Pilot Digital Nano - Cell Volts/Amps

    Weather in the 90's here in upstate NY. Using a LaMotte ColorQ tester. I'm running the pump at 3000 RPM for 6 hours during the day, then for 4 hours at 1800 RPM in the evening. 7/2/18 AM Reading: FCL: .84 TCL: 1.50 PH: 7.4 ALY: 104 CH: 105 CYA: 77 7/4/18 AM reading (two bags of shock the day...
  3. M

    AutoPilot Pool Pilot Digital Nano - Cell Volts/Amps

    Yes - I should clarify that I only cleaned when I saw build-up on the plates. I've cleaned 3? times since new.
  4. M

    AutoPilot Pool Pilot Digital Nano - Cell Volts/Amps

    I have a AutoPilot Pool Pilot Digital Nano and want to make sure it's working as it should. I've read the manual and the cell details for volts and amps - and understand the basics. The Nano was installed about 7 years ago, and I had the main unit replaced 2 years ago due to a faulty display...
  5. autopilot-pool-pilot-volts-amps-troubleshooting.jpg

    autopilot-pool-pilot-volts-amps-troubleshooting.jpg

  6. autopilot-pool-pilot-volts-amps.jpg

    autopilot-pool-pilot-volts-amps.jpg

  7. M

    New Cartridge Filter Question

    Got the new cartridge filter installed this past weekend and am very pleased. Installed very quickly and without issue. I do have a follow-on question regarding backflow... The pool is about 6 feet below the pump equipment. I have a check valve on both the inlet side pipes and there is one...
  8. pool.jpg

    pool.jpg

  9. M

    New Cartridge Filter Question

    Excellent info - thank you! And one clarification for anyone reading in the future, the spec is to tighten the bolt to 150 inch pounds (12.5 foot pounds).
  10. M

    New Cartridge Filter Question

    Thanks for the feedback. The filter is being trucked across the country, so I want to pull the top off and inspect before putting in to service. My torque wrenches were all too large (in measurement capabilities) so I have a 3/8 wrench on the way that will work perfectly. Thanks again for the...
  11. M

    New Cartridge Filter Question

    Thanks for the info. I have: - brand new Hayward SP3200VSP pump (10" length of 2" pipe in front of first fitting/valves) - pump replaces a Hayward 1hp, single speed super pump - Hayward Swimclear C4030 cartridge filter on the way - Heatpump - Chlorine generator - all 2" plumbing on the intake...
  12. M

    New Cartridge Filter Question

    I'm replacing my sand filter with a cartridge filter and have a couple of operating questions not covered in the manual (yes I read the manual). Air bleed - I understand on first start up and after cleaning I need to open the air bleed to let air out and until water comes out. In reviewing...
  13. M

    Digital Nano Help

    The replacement relay fixed the issue! All back in working order.
  14. M

    Digital Nano Help

    I'll take some pics when I install the new relay. I'm wondering if subsequent boards have a beefier relay. The one in mine has a contact rating of 8 amps. As the unit could potentially cycle every 15 minutes at 5 amps that seems awfully close to rating...