  1. L

    GVA actuator issue

    Aside from the wire issue, there was a motor issue. I have received the new one and installed it. I am unfamiliar with adjusting the cams. Right now using the toggle switch it turns 90 degrees left and right of center. I need it to stop in the center and also turn the 90 degrees to the right...
  2. L

    GVA actuator issue

    I cut the wire further down, re connected all the wires and still only working in 1 direction. I guess I will see if I can get a new one under warranty as it’s only 6 months old.
  3. L

    GVA actuator issue

    I noticed that my wire from my valve to my automation panel got cut somehow. I respliced the wires and I used the toggle switch to test it. The valve only works in one direction now. It’s only 6 months old. Any ideas?
  4. L

    Pool cage issue

    Unfortunately I get a build up of pine needles but they are laying in top of the gutter guards and not in the gutter. I usually clean them off twice a year.
  5. L

    Pool cage issue

    It’s coming out along the edges where the support brackets are holding up the screen house.. water is getting in between the gutter and the screen house and dripping out.
  6. L

    Pool cage issue

    Where my pool cage attaches to my super gutter, I get a drip after it rains or even in the morning from dew or condensation. It is annoying. Someone suggested drilling weep holes to get the water out quicker. Anyone had experience with this?
  7. IMG_0285.jpeg

    IMG_0285.jpeg

  8. L

    Circuit name labels

    Anyone have any extra circuit name labels for the Easy Touch wired indoor remote PL4/PLS4 device that they might want to sell for less? I just need 2 labels for the air blower and the light. The one for the spa comes standard and the last button is AUX
  9. L

    Easy touch syncing issue

    Well I turned off everything at the panel. Reinstalled the unit and it started up. My question now is the backlight is always on. Is that the norm now? It is a pl4/psl4 easy touch wired.
  10. L

    Easy touch syncing issue

    I repoaced an easy touch indoor unit that was used that was given to me. First it said mismatched unit Load from outdoor panel. A few minutes later it came on and it says sync. I checked the software. It says the outdoor is 2.1 and the indoor is 0.00. Also the backlight on the indoor unit is...
  11. L

    GVA-24 valve

    Yes that’s the manual and I have a copy of it that came with the valve. What I can’t figure out is howto stop the actuator in the middle at 90 degrees so it doesn’t turn anymore toward the spa return and the right side at the 180 degree mark to shut off the pool return.Everytime I think I have...
  12. L

    GVA-24 valve

    Yes and that’s what I can’t figure out. I guess I will have to try to play with each setting and try to figure it out.
  13. L

    GVA-24 valve

    the spa spillway is always on. The problem is isolating the spa when the heater is on. At present the actuator has to be run by the switch because the cams are in the wrong position, which is what I can’t figure out. This is on the return side. The suction side actuator is fine.
  14. L

    GVA-24 valve

    I put the new valve in and no matter what I try I can’t set the cams correctly. This is a TORK brand if it makes a difference. I want the valve to stop in the center to allow the water to go to my pool and spa. When my spa automation is turned on I need the valve to rotate 90 degrees and stop...
  15. L

    GVA-24 valve

    I put the new valve in today and it was definitely the problem. Now I have to adjust the cams. I need it to stop in the middle so the returns are both open. Then when I turn on the spa the actuator turns to the right and closes off the pool return. What do I need to do to set this up? I haven’t...